Service

Service

Removal

1.Flush pump (36). Stop pump on down stroke if pos- sible.

2.Perform Pressure Relief Procedure, page 3.

3.Remove suction set (147) from pump (36).

36

147

ti7597b

4. Remove paint and drain lines from filter housing.

5.Using a wrench, loosen filter housing fitting (110) and remove housing from pump.

110

ti7119b

6.Using a pliers, remove clip (121).

121

ti7789b

7. Slide cover (124) up.

124

ti7845b

ti7816b

4

311485J

Page 4
Image 4
Graco 287834 important safety instructions Service, Removal