TECHNICAL AND PERFORMANCE DATA (MODEL 222–813)

Ratio

. . . . . . . . . . . . . . . . . . .

. . . . . . . .

55:1 (Quiet Bulldog Air Motor)

Maximum fluid working pressure

. . . . . . . . .

. . . . . . . . . . 347 bar (4950 psi)

Maximum air input pressure . .

. . . . . . . . . . . . . . . . . . .

. . . . . . . . .

. . . . . . . . . . . . 6.3 bar (90 psi)

Pump cycles per 3.8 liters (1 gal.)

. . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . 40

Recommended pump speed for continuous operation

. . . . . . . . . . 40 cycles per min

Maximum recommended pump speed

. . . . . . . . .

. . . . . . . . . . 60 cycles per min

Maximum flow

. . . . . . . . . . . . . . . . . . .

5.7 liters/min (1.5 gpm) at 60 cycles/min

Air motor effective diameter . .

. . . . . . . . . . . . . . . . . . .

. . . . . . . . .

. . . . . . . . . . . . 146 mm (5.75”)

Stroke length

. . . . . . . . . . . . . . . . . . .

. . . . . . . . .

. . . . . . . . . . . . . 120 mm (4.7”)

Displacement pump effective area

. . . . . . . . .

. . . . . . . . . 4.5 cm@ (0.697 in.@)

Maximum pump operating temperature

. . . . . . . . .

. . . . . . . . . . . . 65.5_C (150_F)

Air inlet size

. . . . . . . . . . . . . . . . . . .

. . . . . . . . .

. . . . . . . . . . . . . . . . 3/4 npsm(f)

Fluid outlet size

. . . . . . . . . . . . . . . . . . .

. . . . . . . . .

. . . . . . . . . . . . . . . . . 3/4 npt(m)

Weight

. . . . . . . . . . . . . . . . . . .

. . . . . . . . .

. . . . . . . . . . . . 45.5 kg (100 lb)

Wetted parts

. Carbon Steel; E52100, 41L40, and 4140 Alloy Steel; Acetal;

 

304, 316 and 17–4 PH Grades of Stainless Steel; Ductile Iron;

Zinc and Nickel Plating;PTFEr; Ultra–High Molecular Weight Polyethylene

PTFE

KEY: Fluid Outlet Pressure – Black Curves

A 6.3 bar (90 psi) Air Pressure

Air Consumption – Gray Curves

B

4.9 bar (70 psi) Air Pressure

NOTE:Recommended pump speed for continuous

C

2.8 bar (40 psi) Air Pressure

 

 

operation: 40 cpm

Maximum recommended pump speed (to shaded area): 60 cpm

psi

 

cycles/min

 

 

psi

 

cycles/min

 

 

bar

20

40

60

80

 

bar

20

40

60

80

 

 

 

 

 

5500

 

 

 

 

scfm

5500

 

 

 

 

scfm

385

 

 

 

 

385

 

 

 

 

 

 

 

 

#

 

 

 

 

#

5000

 

 

 

 

m /min

5000

 

 

 

 

m /min

 

 

 

 

 

 

 

 

 

 

350

 

 

 

 

 

350

 

 

 

 

 

4500

 

 

 

 

135

4500

 

 

 

 

135

315

 

 

 

 

3.78

315

 

 

 

 

3.78

4000

A

 

 

 

120

4000

A

 

 

 

120

280

 

 

 

 

3.36

280

 

 

 

3.36

3500

 

 

 

 

105

3500

 

 

 

 

105

245

 

 

 

 

2.94

245

 

 

 

 

2.94

3000

B

 

 

 

90

3000

 

 

 

 

90

210

 

 

A

2.52

210

B

 

A

 

2.52

 

 

75

 

 

75

2500

 

 

 

B

2500

 

 

 

 

175

 

 

 

2.10

175

 

 

 

 

2.10

 

 

 

 

 

 

B

 

2000

 

 

 

 

60

2000

 

 

 

60

140

C

 

 

C

1.68

140

 

 

 

 

1.68

1500

 

 

45

1500

C

 

C

 

45

 

 

 

 

 

105

 

 

 

 

1.26

105

 

 

 

1.26

1000

 

 

 

 

30

1000

 

 

 

 

30

70

 

 

 

 

0.84

70

 

 

 

 

0.84

 

 

 

 

15

 

 

 

 

15

500

 

 

 

 

500

 

 

 

 

35

 

 

 

 

0.42

35

 

 

 

 

0.42

 

 

 

 

 

 

 

 

 

 

0

 

 

 

 

 

0

 

 

 

 

 

gpm0.0

0.5

1.0

1.5

2.0

2.5

gpm0.0

0.5

1.0

1.5

2.0

2.5

liters/min

1.9

3.8

5.7

7.6

9.5

liters/min

1.9

3.8

5.7

7.6

9.5

FLUID FLOW

FLUID FLOW

(TEST FLUID: 1900 CENTIPOISE OIL)

(TEST FLUID: 100,000 CENTIPOISE SEALANT)

To find Fluid Outlet Pressure (bar/psi) at a specific fluid flow (lpm/gpm) and operating air pressure (bar/psi):

1.Locate desired flow along bottom of chart.

2.Follow vertical line up to intersection with selected fluid outlet pres- sure curve (black). Follow left to scale to read fluid outlet pressure.

To find Pump Air Consumption (m#/min or scfm) at a specific fluid flow (lpm/gpm) and air pressure (bar/psi):

1.Locate desired flow along bottom of chart.

2.Read vertical line up to intersection with selected air consumption curve (gray). Follow right to scale to read air consumption.

 29