INSTALLATION
NOTE: Reference numbers and letters in parentheses in the text refer to the callouts in the figures and the parts drawing.
See pages 22 and 23 for accessories available from Graco. If you supply your own accessories, be sure they are adequately sized and pressure- rated to meet the system’s requirements.
The Typical Installation shown on page 4 is only a guide for selecting and installing system components and ac- cessories. Contact your Graco representative or Graco Technical Assistance (see back page) for assistance in designing a system to suit your particular needs.
SYSTEM ACCESSORIES
Refer to the Typical Installation drawing on page 4.
WARNING
A
The
The fluid drain valve assists in relieving fluid pres- sure in the displacement pump, hose, and gun. Triggering the gun to relieve pressure may not be sufficient.
Air and Fluid Hoses
Be sure all air and fluid hoses are properly sized and
Mounting Accessories
Mount the pump (A) to suit the type of installation planned. The pump dimensions and mounting hole lay- outs are shown on pages 30 and 31.
If you are mounting the pump on a ram (B), refer to the manual supplied with the ram unit for installation and op- eration instructions. The ram shown in the Typical Instal- lation is a
By using Pump Mounting Kit
Air Line Accessories
Install the following accessories in the order shown in the Typical Installation, using adapters as necessary:
A pump runaway valve (E) senses when the pump is running too fast and automatically shuts off the air to the motor. A pump which runs too fast can be serious- ly damaged. Install closest to the pump air inlet.
An air line lubricator (F) provides automatic air mo- tor lubrication.
A
An air regulator (H) controls pump speed and outlet pressure by adjusting the air pressure to the pump. Locate the regulator close to the pump, but upstream from the
An air line filter (J) removes harmful dirt and mois- ture from the compressed air supply.
A second
Fluid Line Accessories
Install the following accessories in the positions shown in the Typical Installation, using adapters as necessary:
A fluid drain valve (L) is required in your system to relieve fluid pressure in the hose and gun (see the WARNING at left). Screw the drain valve into the open branch of a tee mounted in the fluid line. Install the drain valve pointing down, but so the handle points up when the valve is opened.
A fluid regulator (M) controls fluid pressure to the gun/valve, and dampens pressure surges.
A gun or valve (N) dispenses the fluid. The gun shown in the Typical Installation is a dispensing gun for highly viscous fluids.
A gun swivel (P) allows freer gun movement.
GROUNDING
WARNING
Before operating the pump, ground the system as explained under FIRE OR EXPLOSION HAZARD and Grounding on page 3.