Graco 309295N important safety instructions Electrode Replacement

Models: 309295N

1 48
Download 48 pages 20.95 Kb
Page 28
Image 28

Repair

Electrode Replacement

WARNING

Electric Shock Hazard

To reduce the risk of fire, explosion, or elec- tric shock, do not operate the spray gun without the electrode installed in the air cap.

1.Prepare the gun for service, page 25.

2.Remove the air cap assembly, page 26.

3.Pull the electrode (9b) out of the back of the air cap, using a needle-nose pliers.

4.Push the new electrode through the air cap hole. Make sure the short end (BB) of the electrode engages the hole (CC) in the back of the air cap. Press the electrode in place firmly with your fingers. See FIG. 10.

5.Install the air cap assembly, page 26.

6.Test gun resistance, page 18.

9b

CC

BB

02013

Fig. 10. Electrode Replacement