Turbine Alternator Removal and Replacement

NOTE: Replace turbine bearings after 2000 hours of operation. Order Part No. 223688 Bearing Kit.

1.Prepare gun for service, page 25.

2.Remove the power supply/alternator assembly, page 32.

3.Disconnect the alternator from the power supply, page 32.

Repair

4.Measure resistance between the two outer termi- nals of the 3-wire connector (B); it should be 2.5-3.5 ohms. If outside this range, replace the alternator coil.

5.Follow the bearing replacement procedure in the bearing kit manual 308034.

6.Install the alternator on the power supply, page 32.

7.Install the power supply/alternator assembly, page 32.