Graco 309550U important safety instructions Flat Spray Tips

Models: 309550U

1 46
Download 46 pages 44.5 Kb
Page 18
Image 18

Flat Spray Tips

Flat Spray Tips

1.

2.

Follow Pressure Relief Procedure, page 15. 4. Reposition tip horizontally or vertically, or install dif- ferent tip size.

Remove air cap (10) and flat spray tip (39). Inspect

o-ring (40).

40

39

10

TI2649A

TI2557A

If tip is stuck, pry off with small screwdriver or pull off with pliers. Tip is hardened to resist damage.

3. To clean, soak tip in compatible solvent, see page

20. Clean gently with tip cleanout tool 15D234, page 44, to fit tip configuration.

TI2648A

Tips marked on back with last 3 digits of part no. See Flat Tip Part No. Reference Guide, page 38.

5. Reinstall air cap hand tight. Cleaning hole align-

ment to tip not important.

18

309550U

Page 18
Image 18
Graco 309550U important safety instructions Flat Spray Tips