Graco 312794E important safety instructions Troubleshooting, Problem, Cause, Solution

Models: 312794E

1 30
Download 30 pages 14.51 Kb
Page 14
Image 14
Troubleshooting

Troubleshooting

Troubleshooting

Relieve the pressure before checking or servicing the equipment.

NOTE: Check all possible problems and causes before disassembling the pump.

Problem

Cause

Solution

 

 

 

 

 

 

Pump output low on both strokes.

Restricted air supply lines.

Clear any obstructions; be sure all shutoff

 

 

valves are open; increase pressure, but do

 

 

not exceed maximum working pressure.

 

 

 

 

Exhausted fluid supply.

Refill and reprime pump.

 

 

 

 

Clogged fluid outlet line, valves, etc.

Clear.

 

 

 

 

Worn piston packing.

Replace. See displacement pump manual

 

 

312792.

 

 

 

Pump output low on only one stroke.

Held open or worn ball check valves.

Check and repair.

 

 

 

 

Worn piston packings.

Replace.

 

 

 

No output.

Improperly installed ball check valves.

Check and repair.

 

 

 

Pump operates erratically.

Exhausted fluid supply.

Refill and reprime pump.

 

 

 

 

Held open or worn ball check valves.

Check and repair.

 

 

 

 

Worn piston packing.

Replace.

 

 

 

Pump will not operate.

Restricted air supply lines.

Clear any obstructions; be sure all shut off

 

 

valves are open; increase pressure, but do

 

 

not exceed maximum working pressure.

 

 

 

 

Exhausted fluid supply.

Refill and reprime pump.

 

 

 

 

Clogged fluid outlet line, valves, etc.

Clear.

 

 

 

 

Damaged air motor.

See air motor manual 312796.

 

 

 

 

Fluid dried on piston rod.

Disassemble and clean pump. See page 15

 

 

and manual 312792. In future, stop pump at

 

 

bottom of stroke.

 

 

 

 

Runaway solenoid has tripped.

Retract solenoid. See air motor manual

 

 

312796.

 

 

 