Troubleshooting

Troubleshooting

Relieve the pressure before checking or servicing the equipment.

F

NOTE: Check all possible problems and causes before disassembling the pump.

Problem

Cause

Solution

 

 

 

 

 

 

Pump fails to operate.

Restricted line or inadequate air sup-

Clear line or increase air supply. Check that

 

ply; closed or clogged valves.

the valves are open.

 

 

 

 

 

Obstructed fluid hose or gun; fluid

Open, clear*; use hose with larger ID.

 

hose ID is too small.

 

 

 

 

 

 

Fluid dried on the displacement rod.

Clean; always stop the pump at the bottom

 

 

of its stroke; keep the wet-cup 1/3 filled with

 

 

Graco throat seal liquid (TSL).

 

 

 

 

Dirty, worn, or damaged air motor

Clean or repair air motor. See manual

 

parts.

312796.

 

 

 

 

 

DataTrak models only: Air valve can-

Enable runaway protection (See DataTrak

 

not cycle because solenoid pin is

Operation, Setup Mode, page 20). Bleed

 

extended

air from motor. Press

on the DataTrak

 

 

 

 

display to retract solenoid pin.

 

 

 

Pump operates, but output is

Restricted line or inadequate air sup-

Clear line or increase air supply. Check that

low on both strokes.

ply; closed or clogged valves.

the valves are open.

 

 

 

 

 

Obstructed fluid hose or gun; fluid

Open, clear*; use hose with larger ID.

 

hose ID is too small.

 

 

 

 

 

 

Worn packings in displacement

Replace packings. See manual 312794.

 

pump.

 

 

 

 

 

Pump operates, but output is

Held open or worn ball check valves

Clear valve; replace packings. See manual

low on downstroke.

or piston packings.

312794.

 

 

 

 

 

Erratic or accelerated pump

Exhausted fluid supply.

Refill and prime.

 

speed.

 

 

 

Held open or worn ball check valves

Clear valve, replace packings; see manual

 

 

or packings.

312794.

 

 

 

 

Fluid being pumped is visible

Worn throat packings.

Replace throat packings. See manual

in the TSL reservoir.

 

312794.

 

 

 

 

 

*To determine if the fluid hose or gun is obstructed, relieve the pressure. Disconnect the fluid hose and place a con- tainer at the pump fluid outlet to catch any fluid. Turn on the air just enough to start the pump. It the pump starts when the air is turned on, the obstruction is in the hose or gun.