Parts

245846, Xtreme MixDosing Valve

 

1

 

 

 

7 6

 

5

2

 

 

 

 

 

 

 

 

8

17

19

8

 

 

14

 

 

 

 

 

 

12

8

18

6

4

 

 

 

 

 

 

 

 

 

 

 

 

4

11

 

 

 

8

 

 

7

3

109

 

16

4

 

 

 

 

 

 

 

13

 

 

10

8

 

 

 

 

 

 

 

 

 

3

 

 

 

 

 

15

 

 

25 9

 

 

 

 

 

 

 

 

 

4

 

 

24 10

 

 

 

 

25

9

 

 

 

 

 

 

 

 

 

 

 

26

9

 

 

23

 

 

 

 

 

 

5

27

5

 

 

101

TI2299A

1.Apply pipe sealant to non-swiveling pipe threads.

2.Apply lubricant to threads, o-rings, and seals.

3

Apply blue thread lock. Thread to bottom.

4

Torque to 5-7 ft-lbs (7-9 N•m).

5

Torque to 30-40 ft-lbs (41-54 N•m).

6

Tighten packing nut 1/4 turn after nut bottoms out;

 

145-155 in./lbs (16-18 N•m). Check packing nut tightness

 

about once a month. Keep packing nut filled with TSL.

7

Lubricate and press piston evenly into cylinder.

8Clean needle (10) and packing cavity before reinstalling, packings (17, 18, 19). Lubricate packings and install with lips facing down away from packing nut (7) in order shown.

9Replace o-rings (25) when seat housing (26) is removed.

10Inspect reversible seat for damage. If one side is worn, reverse seat.

313342D

9

Page 9
Image 9
Graco 313342D important safety instructions 245846, Xtreme Mix Dosing Valve, 109 101