Repair
Repair
Required Tools
• | Large vise |
• Set of adjustable wrenches | |
• | |
• 1/2 in. bit socket | |
• | Rubber mallet |
a.Remove upper ball cage (12), spring (11), ball (10),
b.Press lower ball (10) off seat (9) from fluid inlet and drain the inlet housing (7).
c.Remove
• | Torque wrench |
• | 2 in. and 3 in. sockets |
11
12
• | |
• | Removable strength thread locker |
Inlet Housing Disassembly
1.Relieve pressure and flush system. See Pressure Relief Procedure and Flushing, page 7.
2.Remove inlet hose and drain inlet housing (7).
13
8
6
r_257891_3a0019_4h
3.Remove inlet cap (13) from inlet housing (6), and remove
10
8
9
8
12
11
10
9
8
6
r_257891_3a0019_5h
d.Clean all parts in a compatible solvent. Lay them in order for easier reassembly. Inspect each ball and seat for nicks or scratches; replace as required.
Inlet Housing Assembly
1.Install inlet housing components in inlet housing (6).
2.Install