Install the Solenoid Valves
1.Disconnect main power. Open the Control Box.
2.Install the two solenoid valves (713) in positions A2 and A3 as shown below.
3.Connect the wires. Solenoid A2: black to pin 7 and
red to pin 8. Solenoid A3: black to pin 9 and red to pin 10.
4.Remove the plugs from the ports at the bottom of the solenoid manifold. Install the male connectors (718).
5.Install the air tubing. See page 3.