3A1332A 3
Install the Air Tubing
NOTE: The kit includes 6 ft (1.83 m) of red tubing (715)
and 6 ft (1.83 m) of green tubing (716). Cut the tubing to
the correct lengths to make the following connections.
1. Connect red 5/32 in. (4 mm) OD tubing between the
B connector of solenoid A2 and the CLOSE fitting of
valve A2. Repeat for solenoid A3 and valve A3.
2. Connect green 5/32 in. (4 mm) OD tubing between
the A connector of solenoid A2 and the OPEN fitting
of valve A2. Repeat for solenoid A3 and valve A3.
3. Close the Control Box. Restore power.