Technical Data

Technical Data

Husky 2200 Diaphragm Pump

 

 

 

 

 

US

Metric

Maximum fluid working pressure

125 psi

0.86 MPa, 8.6 bar

Air pressure operating range

20 to 125 psi

0.14 to 0.86 MPa, 1.4 to 8.6 bar

Air inlet size

 

3/4 in.

npt(f)

 

Air exhaust size

 

1 in.

npt(f)

 

Fluid inlet and outlet size (ANSI/DIN

2 in

50 mm

flange)

 

 

 

 

Maximum suction lift (reduced

Wet:

31 ft

Wet:

9.4 m

if balls don’t seat well due to

Dry:

16 ft

Dry:

4.9 m

damaged balls or seats, lightweight

 

 

 

 

balls, or extreme speed of cycling)

 

 

 

 

Maximum size pumpable solids

1/4 in.

6.3 mm

Minimum ambient air temperature

32° F

0° C

for operation and storage.

 

 

 

 

NOTE: Exposure to extreme low

 

 

 

 

temperatures may result in damage

 

 

 

 

to plastic parts.

 

 

 

 

 

 

 

 

 

Air consumption

 

 

 

 

Standard diaphragms

70 scfm at 70 psi; 100 gpm

2.0 m3/min at 0.48 MPa, 4.8

 

 

 

bar, 379 lpm

Overmolded diaphragms

75 scfm at 70 psi, 100 gpm

2.1 m3/min at 0.48 MPa, 4.8

 

 

 

bar, 379 lpm

Maximum air consumption

 

 

 

 

Standard diaphragms

140 scfm

4.0 m3/min

Overmolded diaphragms

157 scfm

4.4 m3/min

Noise (dBa)

 

 

 

 

Sound power measured per ISO-9614–2. Sound pressure was tested 3.28 ft (1 m) from equipment.

Sound Power

95.2 at 70 psi and 50 cpm

95.2 at 4.8 bar and 50 cpm

 

101.8 at 100 psi and full flow

101.8 at 7.0 bar and full flow

Sound Pressure

87.3 at 70 psi and 50 cpm

87.3 at 4.8 bar and 50 cpm

 

94.7 at 100 psi and full flow

94.7 at 7.0 bar and full flow

Fluid flow per cycle

 

 

 

 

Standard diaphragms

1.6 gallons

6.1 liters

Overmolded diaphragms

1.3 gallons

4.9 liters

Maximum free-flow delivery

 

 

 

 

Standard diaphragms

200 gpm

757 lpm

Overmolded diaphragms

200 gpm

757 lpm

22

3A2578B

Page 22
Image 22
Graco 3A2578B Technical Data, Husky 2200 Diaphragm Pump, Air consumption, Maximum air consumption, Noise dBa