26 310564
Technical Data

4:1 Ratio Glutton Pumps

Category Data
Maximum Fluid Working Pressure 2.4 MPa, 24.5 bar (350 psi)
Air Operating Range 0.17–0.6 MPa, 1.7 – 6.2 bar (25 – 90 psi)
Fluid Flow at 60 Cycles per Minute 21.2 liter/min (5.6 gpm)
Cycles Per Liter (gallon) 2.7 (10.4)
Maximum Recommended Pump
Speed
60 cycles per minute
Wetted parts Stainless Steel, PTFE, Ultra High Molecular Weight Polyethylene,
polypropylene, Nylon
Vitonr is a registered trademark of the Du Pont Co.

Performance Chart

012345678
60
40
20
0
FLUID FLOW
l / min0 7.5 15 22.5 30
GPM
0
AIR FLOW
SCFM m3/min
0.56
1.12
1.68
28
21
14
7
0
FLUID OUTLET
PRESSURE
Bar PSI
400
200
300
100
20 40 600 CPM
To find pump air consumption (CFM, m3/min) specific
delivery (GPM, lpm) and operating air pressure (psi/MPa/
bar):
1. Locate desired delivery along bottom of chart.
2. Read vertical line up to intersection with selected air con-
sumption curve. Follow right to scale and read air con-
sumption.
To find outlet pressure (psi/MPa/bar) at a specific delivery
(GPM, lpm) and operating air pressure (psi/MPa/bar):
1. Locate desired delivery along bottom of chart.
2. Read vertical line up to intersection with selected fluid
outlet pressure curve. Follow left to scale and read outlet
pressure.
0
3.75 11.25 18.75 26.25
10
30
50 1.40
0.84
0.28
A
B
C
KEY: Fluid Outlet Pressure: black curves
Air Consumption: gray curves
Aat 100 psi (0.7 MPa, 7 bar) air pressure
Bat 70 psi (0.48 MPa, 4.9 bar) air pressure
Cat 40 psi (0.28 MPa, 2.8 bar) air pressure
A
B
C