8 310564
Setup
Connect the Fluid Lines
Fig. 1. Connect system fluid supply line to the circula-
tion package at fluid supply inlet (A). Close filter ball
valves (E) to isolate the circulation package from the
main fluid supply line.
Connect circulation package to the system fluid return
line at fluid return outlet (T). Close fluid return valve (U)
to isolate the circulation package from the main fluid
return line.
Connect the Air Line
Fig. 1. Bring an air supply line from the facility air
supply (Z) to the circulation package location. Be sure
all air lines are properly sized and pressure-rated for
the system. Use only electrically conductive hoses. Air
hose should have a 1/2 npt(m) thread.
Install a bleed-type shutoff valve (W) in the air line to
isolate the air line components for servicing. Install a
moisture trap and drain valve (Y) to help remove
moisture and contaminants from the compressed air
supply.
Using the Quick Connectors
Fig. 2. To open a quick connector (A), loosen the
captive screw (B) and open the connector. Slide the
desired component into or out of the connector, close,
and tighten the screw.
06278
Fig. 2
B
A