Technical Data

Technical Data

Category

Data

Ratio

Maximum fluid working pressure Maximum air input pressure Fluid flow at 60 cycles per minute Maximum pump operating temperature Wetted parts

15:1

105 bar (10.5 MPa, 1500 psi)

7 bar (0.7 MPa, 100 psi)

1.9liters/min (0.5 gpm) 82_C (180_F)

Refer to manual 306±981.

Sound Pressure Levels (dBa) (measured at 1 meter from unit)

 

Input Air Pressures at 15 cycles per minute

 

 

 

 

Air Motor

2.8 bar (0.28 MPa, 40 psi)

4.8 bar (0.48 MPa, 70 psi)

7 bar (0.7 MPa, 100 psi)

 

 

 

 

Monark

73.3 dB(A)

75.9 dB(A)

77.7 dB(A)

 

 

 

 

Sound Power Levels (dBa)

(tested in accordance with ISO 9614±2)

Air Motor

Input Air Pressures at 15 cycles per minute

2.8 bar (0.28 MPa, 40 psi)

4.8 bar (0.48 MPa, 70 psi)

7 bar (0.7 MPa, 100 psi)

 

 

 

Monark

87.0 dB(A)

89.7 dB(A)

91.4 dB(A)