Graco ti1109 important safety instructions Technical Data

Models: ti1109

1 20
Download 20 pages 18.38 Kb
Page 19
Image 19

 

Technical Data

Technical Data

 

Maximum Air Inlet Pressure

100 psi (0.7 MPa, 7 bar)

Maximum HVLP/Compliant Inbound Air Pressure

 

HVLP

30 psi (0.21 MPa, 2.1 bar)*

Compliant

35 psi (0.24 MPa, 2.4 bar)

Air Consumption

 

Conventional

12.2 CFM at 43 psi (0.3 MPa, 3.0 bar)

HVLP

11.2 CFM at 30 psi (0.21 MPa, 2.1 bar)

Compliant

10.4 CFM at 35 psi (0.24 MPa, 2.4 bar)

Fluid and Air Operating Temperature Range

32°F to 109°F (0°C to 43°C)

Spray Gun:

 

Air Inlet

1/4 npsm (R1/4-19)

Fluid Inlet

3/8 npsm (R3/8-19)

Weight with cup

2.1 lbs (1.0 kg)

Sound Data:

 

Conventional

 

Sound pressure at 43 psi (0.3 MPa, 3.0 bar)

78.22 dB(A)**

Sound power at 43 psi (0.3 MPa, 3.0 bar)

86.68 dB(A)**

HVLP

 

Sound pressure at 30 psi (0.21 MPa, 2.1 bar)

81.8 dB(A)**

Sound power at 30 psi (0.21 MPa, 2.1 bar)

88.7 dB(A)**

Compliant

 

Sound pressure at 35 psi (0.24 MPa, 2.4 bar)

74.68 dB(A)**

Sound power at 35 psi (0.24 MPa, 2.4 bar)

83.07 dB(A)**

Siphon Cup Size

1 qt. (0.95 liter)

Wetted Parts

303 stainless steel, 17-4 PH stainless

 

steel, PEEK, acetal, UHMWPE

*Produces 10 psi (0.07 MPa, 0.7 bar) spraying pressure at air cap.

**All readings were taken with the fan valve fully open (fan full size) at the assumed operator position. Sound power was tested per ISO 9614-2.