Graco TI12954a Tubing Chart, Ending, Tube OD, Color, Description, Starting Point, in. mm

Models: TI12743a TI12954a

1 20
Download 20 pages 46.39 Kb
Page 12
Image 12

Schematic Diagrams

Table 1: Tubing Chart

 

 

 

Ending

Tube OD

 

Color

Description

Starting Point

Point

in. (mm)

Tube Ref. No.

 

 

 

 

 

 

Green

Dose A On

A2

A2

5/32 (4)

336

 

 

 

 

 

 

Green

Dose B On

A4

A4

5/32 (4)

336

 

 

 

 

 

 

Green

Purge A On

A6

A6

5/32 (4)

336

 

 

 

 

 

 

Green

Purge B On

A8

A8

5/32 (4)

336

 

 

 

 

 

 

Green

Dump A

DA

DA

5/32 (4)

Included in optional

 

 

 

 

 

Dump Valve Kit

Green

Dump B

DB

DB

5/32 (4)

15V821

 

 

 

 

 

 

 

 

 

 

 

Red

Dose A Off

B1

B1

5/32 (4)

337

 

 

 

 

 

 

Red

Dose B Off

B3

B3

5/32 (4)

337

 

 

 

 

 

 

Red

Purge A Off

B5

B5

5/32 (4)

337

 

 

 

 

 

 

Red

Purge B Off

B7

B7

5/32 (4)

337

 

 

 

 

 

 

Natural

Solenoid Air Supply

13

13

1/4 (6)

334

 

 

 

 

 

 

Natural

Gun Flush Box 1 Pressure

GFB1-A

GFB1-A

5/32 (4)

 

 

Switch Signal

 

 

 

 

 

 

 

 

 

 

Natural

Gun Flush Box 2 Pressure

GFB2-A

GFB2-A

5/32 (4)

 

 

Switch Air

 

 

 

 

 

 

 

 

 

 

Natural

Gun Flush Box 1 Trigger

GFB1-C

GFB1-C

5/32 (4)

 

 

Air

 

 

 

 

 

 

 

 

 

 

Natural

Gun Flush Box 2 Trigger

GFB2-C

GFB2-C

5/32 (4)

Included in optional

 

Air

 

 

 

 

 

 

 

Gun Flush Box Kit

 

 

 

 

 

Natural

Gun Flush Box 1 Supply

GFB1-P

GFB1-P

5/32 (4)

15V826

 

Air

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Natural

Gun Flush Box 2 Supply

GFB2-P

GFB2-P

5/32 (4)

 

 

Air

 

 

 

 

 

 

 

 

 

 

Natural

Gun Flush Box 1 Safety

GFB1-S

GFB1-S

5/32 (4)

 

 

Interlock

 

 

 

 

 

 

 

 

 

 

Natural

Gun Flush Box 2 Safety

GFB2-S

GFB2-S

5/32 (4)

 

 

Interlock

 

 

 

 

 

 

 

 

 

 

Natural

Gun 1 Atomizing Air

ATOM-1

ATOM-1

1/4 (6)

User supplied. Con-

 

 

 

 

 

nects air flow switch to

Natural

Gun 2 Atomizing Air

ATOM-2

ATOM-2

1/4 (6)

gun air shutoff valve.

 

 

 

 

 

 

 

 

 

 

 

Natural

Purge Air Supply

Use as a separate line

AT

1/4 (6)

338

 

 

connected directly to the

 

 

 

 

 

main shop air line. Do

 

 

 

 

 

not connect to the unit’s

 

 

 

 

 

main air supply or to the

 

 

 

 

 

air manifold (335).

 

 

 

 

 

 

 

 

 

12

312786G

Page 12
Image 12
Graco TI12954a, TI12743a Tubing Chart, Ending, Tube OD, Color, Description, Starting Point, in. mm, Tube Ref. No