Installation

Stand Mount

Plumbing

Mount the pump in the accessory pump stand (B). Use Part No. 253692 Stand for 1000, 1500, and 2000cc Pumps (see FIG. 2, page 9) and Part No. 218742 Stand for 3000 and 4000cc Pumps (see FIG. 3, page 10).

See Mounting Stand Hole Layouts on page 24. Secure the stand to the floor with M19 (5/8 in.) bolts which engage at least 152 mm (6 in.) into the concrete floor to prevent the pump from tipping.

Wall Mount

1.Ensure the wall is strong enough to support the weight of the pump assembly and accessories, fluid, hoses, and stress caused during pump operation.

2.Ensure that the mounting location has sufficient clearance for easy operator access.

3.Position the wall bracket at a convenient height, ensuring that there is sufficient clearance for the fluid suction line and for servicing the lower.

4.Drill four 7/16 in. (11 mm) holes using the bracket as a template. Use any of the three mounting hole groupings in the bracket. See 255143 Wall Mount Bracket, page 25.

5.Bolt the bracket securely to the wall using bolts and washers designed to hold in the wall’s construction.

6.Attach the pump assembly to the mounting bracket.

7.Connect air and fluid hoses.

Install a fluid shutoff valve (D) between the mix tank (A) and the pump.

When using a stainless steel pump, use stainless steel plumbing to maintain a corrosion-resistant system.

Flush Before Using Equipment

The equipment was tested with lightweight oil, which is left in the fluid passages to protect parts. To avoid con- taminating your fluid with oil, flush the equipment with a compatible solvent before using the equipment. See Flushing, page 12.