Installation

Assembling the Wall Mount Unit

Install the wall bracket (2) 5 ft (1.52 m) above the floor. Use the mounting hole layout shown on page 18. Be sure the wall is strong enough to support the weight of the pump and hoses, any accessories, the fluid, and stress caused by pump operation.

The following steps apply to Model 236–414 only: Apply thread sealant and screw the connector (28) into the pump’s fluid inlet. See Fig. 2.

Slide the bung plug (31) onto the suction tube (33). Push the 0.625 in. (16 mm) OD suction tube into the elbow (30) to its full depth, then tighten the nut secure- ly with a wrench.

Push the 0.5 in. (13 mm) OD flexible tube (29) into the elbow (30) to its full depth, then tighten the nut secure- ly with a wrench. Push the other end of the flexible tube into the connector (28) to its full depth, then tight- en the nut securely with a wrench.

Screw the bung plug (31) into the drum bung opening. Adjust the suction tube (33) so the end of the tube is about 1/2 in. (13 mm) off the bottom of the drum, and secure using the thumbscrew (32).

22

28 3

31

32

Insert tube (29) into connector (28) ￿ to full depth and tighten nut

securely with wrench.

Insert tube (33) into elbow (30) to

2 full depth and tighten nut securely with wrench.

3Apply thread sealant to male threads.

Fig. 2

2

29 ￿

30

33

2

￿2773

￿￿8￿￿￿￿ 5