Contents
Main
308293
INSTRUCTIONS-PARTS
Model
Optimiser HVLP Spray Gun
Table
of Contents
Symbols
Warning Symbol
Caution Symbol
WARNING
PRESSURIZED EQUIPMENT HAZARD
FIRE AND EXPLOSION HAZARD
TOXIC FLUID HAZARD
TERMS:
Standard
CHART 1: GUN ASSEMBLIES, Series B
Gun Assemblies
(See TERMS above)
Gun Assemblies available as Build to Order
Standard
See page 6 for needle assembly replacement tips.
recommended torque to install molded fluid nozzle in the spray gun is 35 in-lbs (4 N
* Maximum
See
CHART 3: OPTIONAL ORIFICE PURGE SST NEEDLE
Use
CHART 4: NEEDLE ASSEMBLY REPLACEMENT TIPS
Selecting the Proper Needle/Nozzle/Air Cap Set
Selection Problems and Solutions
Air
Flow and Atomizing Pressure
Air Flow
Atomizing Air Pressure
Typical
Installation
The M-1265 HVLP Spray Gun
Ventilate the Spray Booth
1. Connect the Air Line
If your regulated air source does not have a filter
,
2. Connect the Fluid Hose
3. Flush the Spray Gun.
4. Relieve the Pressure. 5. Position the Air Cap
(continued)
Continued on the next page.
For continuous spraying,
Page
Operation
Pressure Relief Procedure
Applying the Fluid
WRONG RIGHT
General System Maintenance
Page
Page
Page
Troubleshooting
Page
Items Needed for Service
Disassembly
Page
Assembly
Page
Parts
Drawing
Parts
List
Manual
which may be purchased separately
Repair Kit 236007
100 psi (0.7 MPa, 7 bar) Maximum Inlet Pressure 330 psi (21210 kPa, 0.22.1 bar)
Regulated Pressure Range
100 psi (0.7 MPa, 7 bar) Maximum Working Pressure
300 psi (2.1 MPa, 21 bar) Maximum Working Pressure
250 psi (1.7 MPa, 17.4 bar) Maximum
(with check valve)
Dimensions
Technical
Data
Page
Page
Page
Graco
W
MINNEAPOLIS, MN
GRACO INC. P.O. BOX 1441
All
Graco
32 308293
arranty and Limitation of Liability
Phone Numbers
, or call this number to identify the distributor closest to you: 18003674023 T