TECHNICAL DATA
| 5:1 MONARK | 10:1 PRESIDENT | 10:1 PRESIDENT |
| (Cart Mounted) | (Cart Mounted) | (Tank Mounted) |
Air Pressure | 40 to 180 psi (3 to 12 bar) | 40 to 180 psi (3 to 12 bar) | 40 to 180 psi (3 to 12 bar) |
|
|
|
|
Maximum Air Pressure To | 300 psi (21 bar) | 300 psi (21 bar) | 300 psi (21 bar) |
Regulator |
|
|
|
Maximum Pump Air Pressure | 180 psi (12 bar) | 180 psi (12 bar) | 180 psi (12 bar) |
|
|
|
|
Maximum Working Pressure | 900 psi (62 bar) | 1800 psi (124 bar) | 1800 psi (124 bar) |
|
|
|
|
Maximum Flow Rate | 2.5 gpm (10 lpm) | 3.0 gpm (11 lpm) | 3.0 gpm (11 lpm) |
(Continuous Duty) |
|
|
|
Pump Cycles/Displacement | 28 cycles/gallon | 20 cycles/gallon | 20 cycles/gallon |
| (8.0 cycles/liter) | (5.3 cycles/liter) | (5.3 cycles/liter) |
Maximum Air Consumption | 25 cfm (94 lpm) | 40 cfm (151 lpm) | 40 cfm (151 lpm) |
|
|
|
|
Unit Weight | 97 lbs (44 kg) | 108 lbs (49 kg) | 172 lbs (78 kg) |
|
|
|
|
Overall Dimensions |
|
|
|
Length | 29 in. (737 mm) | 29 in. (737 mm) | 36 in. (914 mm |
Width | 27 in. (686 mm) | 27 in. (686 mm) | 25 in. (635 mm) |
Height | 46 in. (1168 mm) | 46 in. (1168 mm) | 43 in. (1092 mm) |
|
|
|
|
Maximum Inlet Water | 200_ F (93_ C) | 200_ F (93_ C) | 200_ F (93_ C) |
Temperature |
|
|
|
Inlet Hose Connection | 3/4 in. garden hose (f) | 3/4 in. garden hose (f) | 3/4 in. garden hose (f) |
|
|
|
|
Wetted Parts |
|
|
|
High Pressure Hose | Acrylonitrile and |
| |
Pressure Washer | Anodized aluminum, Aluminum or bronze alloys, Brass Copper, | ||
(including fittings) | Vitonr, | ||
| thermoplastic,PTFEr, Carbon steel, Zinc with or without yellow chromate plate | ||
| PTFE and Vitonr are tradenames of the DuPont Company. |
|
ACCESSORIES
(Must be purchased separately)
Air Line Filter | |
(1/2 npt inlet and outlet) |
|
250 psi (17 bar) maximum working pressure. |
|
Air Line Lubricator | |
(1/2 npt inlet and outlet) |
|
250 psi (17 bar) maximum working pressure. |
|
Bleed Type Master Valve (Required) | |
(1/2 npt inlet and outlet) |
|
300 psi (21 bar) maximum working pressure. |
|
Pump Runaway Valve |
|
(3/4 npt inlet and outlet)
180 psi (12 bar) maximum working pressure. Shuts off air to the pump automatically if it senses that the pump is running too fast, a condition caused by a depleted water supply.
Grounding Wire | |
25 ft. (7.6 m) 12 ga wire |
|
Grounding Clamp | |
Backflow Preventer |
|
Prevents the backup of contaminated water into the fresh supply. Installs upstream of the pump.
Inlet Pressure Regulator | ||
Regulates inlet water pressure to 60 psi (4 bar) | ||
maximum. |
|
|
Wall Mount Bracket | ||
Foamer |
| |
| ||
Non evaporating solvent for wet cup |
| |
Quart (.9 Liter) |
| |
Gallon (3.8 Liter) |
|