Maintenance
Clean Dispensing Valve and System Daily
CAUTION
Be sure that the solvent you use is compatible with the fluid being dispensed, to avoid clogging the valve’s fluid passages.
An important part of the care and maintenance of your automatic dispensing valve is proper flushing. Flush the valve daily with a compatible solvent until all traces of fluid are removed from the valve passages. Follow the Pressure Relief Procedure on page 5 before flushing.
Clean the outside surfaces of the valve by wiping with a soft cloth dampened with a compatible solvent.
CAUTION
Never immerse the entire dispensing valve in solvent. Immersing in solvent removes lubricants and tends to damage packings.
To remove a hardened particle from the orifice, blow air through the orifice from the front.
Service
Needle, Seat and Packings
To clean or replace the needle (18), its seat (17) or packings (19 or 15), proceed as follows:
1.Follow Pressure Relief Procedure on page 5
2.Remove retaining nut (3).
3.Remove valve housing (4).
4.Remove valve seat (2) and
5.Remove gun needle (18).
6.Remove seal nut (21).
7.Remove
8.Clean all parts.
9.Lubricate
10.Install seal nut (21).
11.Install gun needle (18).
12.Install
13.Install retaining nut (3).
Air Piston, Spring and Seals
Follow the Pressure Relief Procedure on page 5, then remove the valve as explained, preceding. Re- move the air cylinder cap (7), take out the spring (8) and pull the piston (10) out. Clean and inspect all parts. Check the piston
Repair Kit
Repair Kit 238340 includes the parts listed with an * in Parts on page 11.