3105482
WARNING

FIRE AND EXPLOSION HAZARD

Flammable fumes, such as solvent and paint fumes, in work area can ignit e or explode. Tohelp pre-
vent fire and explosion:
DUse equipment only in well ventilated area.
DDo not fill fuel tank while engine is runningor hot ; shut off engineand let it cool. Fuel is flam mable
and can ignite or explode if spilled on hot surface.
DWhen flammable liquid is sprayed or used for flushing or cleaning, keep sprayer at leas t 20 feet (6
m) away from explosive vapors.
DEliminate all ignition sources; such as pilot lights, cigarettes, portable electric lamps, and plastic
drop cloths (potential static arc).
DKeep work area free of debris, including solvent, rags and gasoline.
DDo not plug or unplug power cords, or turn power or light switches on or off when flammable f umes
are present.
DGround equipment and conductive objects in work area. See Grounding instruct ions.
DUse only grounded hoses.
DHold gun firmly to side of grounded pail when triggering into pail.
DIf there is static sparking or you feel a shock, stop oper ation immediately. Do not use equipment
until you identify and correct the problem.

INJECTION HAZARD

High--pressurefluid f rom gun, hose leaks, or ruptured components will pierce skin. This may look like
just a cut, but it is a serious injury that can result in amputation. Get immediate medical attention.
DDo not point gun at anyone or at anypar t of the body.
DDo not put your hand over the spray tip.
DDo not stop or deflect leaks with your hand, body, glove, or rag.
DDo not spray without tip guard and trigger guard installed.
DEngage trigger lock when not spraying.
DFollow Pressure Relief Procedure in this manual, when you stop spraying and before c leaning,
checking, or servicing equipment.

PRESSURIZED EQUIPMENT HAZARD

Fluid from the gun/dispense valve, leaks, or ruptured components can splash in the eyes or on skin
and cause serious injury.
DFollow Pressure Relief Procedure in this manual, when you stop spraying and before c leaning,
checking, or servicing equipment.
DTighten all fluid connections before operating the equipment.
DCheck hoses, tubes, and couplings daily. Replace worn or damaged parts immediately.

MOVING PARTS HAZARD

Moving parts can pinch or amputate fingers and other body parts.
DKeep clear of moving parts.
DDo not operate equipment with protective guards or covers removed.
DPressurized equipment can start without warning. Before checking, moving, or servicing equip-
ment, follow the Pressure Relief Procedure in this manual. Disconnect power or air supply.