3105484
General Repair Information
WARNING
MOVING PARTS HAZARD
Toreduce risk of s erious injury,do not
touch moving parts with fingers or tools
while testing repair. Shut off sprayer
when repairing. Install all covers, gas-
kets, screws and washers before operat-
ing sprayer.
1. Keep all screws, nuts, washers, gaskets, and
electrical fittings removed during repair proce-
dures. These parts are not normally provided with
replacement assemblies.
2. Testrep air after problem is corrected.
3. If sprayer does not operate properly,review
repair procedure to verify procedure was done
correctly. If necessary, see Troubleshooting Guide,
page 6, for other possible solutions.
WARNING
HOT SURFACES HAZARD
EXPLOSION HAZARD
Hydraulic system and engine may be
very hot during operation and could burn
skin if touched.
Flammable materials spilled on hot
engine could cause fire or explosion.
Have belt guard in place during opera-
tion to reduce risk of pinching or loss of
fingers.
4. Installbelt guard before operation of sprayer
and replace if damaged. Belt guard reduces risk of
pinching and loss of fingers; see preceding
WARNING.

Grounding

Groundsprayer withgrounding clamp t o earth ground for
safe sprayer operation. Fig. 1.
Fig. 1 06250
water pipe, steel
sign post, or metal
light pole
grounding
clamp

SAE O-Ring Installation

1. Unscrew lock nut to touch fitting.
2. Lubricate o-ring
3. Screw in fitting hand tight.
4. Unscrew fitting until oriented properly.
5. Tighten lock nut to indicated torque.
(Make sure washer is seated
properly without pinching o-ring).