Clearing Tip Clogs
1.Release trigger, put safety ON. Rotate SwitchTip. Take safety OFF. Trigger gun to clear clog. Never point gun at your hand or into a rag!
ti10166a | ti13033a | ti10167a |
|
2.Put safety ON. Return SwitchTip to original position. Take safety OFF and continue spraying.
ti10166a | ti13034a | ti10167a |
|
|
WatchDog™ Protection System (Not Available on All Units)
Pump stops automatically when material pail is empty.
To Activate:
1.Perform Startup.
2.Premium units with digital display:
Turn WatchDog switch ON and WD ON displays. EMPTY displays/flashes and pump stops when Watchdog protection system detects an empty material pail.
ti6224a
TI
3.Turn WatchDog switch OFF. Add material or reprime sprayer. Turn pump switch OFF and ON to reset WatchDog protection system. Turn WatchDog switch back ON to continue to monitor material level.
WatchDog™ Protection System (Not Available on All Units)
Hose Reel
Be sure to keep your head clear of hose reel while winding up hose.
1. Make sure hose is routed through hose guide.
ti13504a
2.Lift and turn pivot lock 90 to unlock hose reel. Pull on hose to remove it from hose reel.
ti13501a
3.Pull reel handle down and turn clockwise to reel in hose.
ti13502a
ti13503a
NOTE: The hose reel can be locked into two posi-
tions: Usage (A) and Storage (B).
(A)(B)
ti13563a
3A0242A | 9 |