Installing and Changing Spray Tips (2340)

Installing and Changing Spray Tips (2340)

WARNING

,

To reduce the risk of serious bodily injury

including fluid injection or splashing in the eyes or onto the skin, use extreme caution when

changing spray tips.

ALWAYS follow the

procedure below.

 

1.Follow the Pressure Relief Procedure.

2.Point the gun and wand away from yourself and anyone else.

3.Without holding your hand over the spray tip (A), pull back the quick coupler ring (B). Remove the old tip and/or install a new one, and then release the ring. See Figure 3.

4.Be sure the tip is secure before starting to spray again.

5.Tip holding holes are provided on the chassis.

CAUTION

To avoid blowing the o–ring out of the quick coupler, due to the high pressure in the system, never operate the pressure washer without a tip securely mounted in the quick coupler.

A

B

Figure 3