Graco Inc 800-902, Serles A, 800-903, 800-904, 800-905, 720, 308-533, 710, 1020 Fluid Injection Hazard

Models: 1010 1020 710 308-533 720 800-905 800-904 800-902 800-903 Serles A

1 20
Download 20 pages 52.89 Kb
Page 2
Image 2

HIGH PRESSURE SPRAY CAN CAUSE SERIOUS INJURY FOR PROFESSIONAL USE ONLY. OBSERVE ALL WARNINGS.

Read and understand all instruction manuals beforeoperating equipment.

FLUID INJECTION HAZARD

General Safety

mis pressure washer generates very high fluid pressure. Spray from the gun, leaks or ruptured components can inject fluid throughyour skin and into your body and cause extremely seriousbodily injury including the need for amputation. Also,fluidinjectedor splashed into the eyes or on skinthe can cause serious damage.

NNER point the spray gun or wand at anyone or at any part of the body.NNER put hand or fingers over the spray tip.

ALWAYSfollow thePressure ReliefProcedure,before cleaning or servicing any part of the sprayer.

NNER try to stop or deflect leaks withyour hand or body.

Be sure equipment safety devices are operating properly before eachuse.

Medical Treatment

If any fluid appears to penetrate your skin, get

EMERGENCY MEDICALTREATMENTATONCEDO. NOT TREATAS A SIMPLE CUT. Tell thedoctor exactly what fluid was injected.

NOTE TO PHYSICIAN lnjectionin the skinis a traumatic injur,! It IsImportantto treat the injury surglcaily as soon as possible. Do not delay treatment to research toxicity Toxicity is a concern with some exotic coatings injected direct& into the bloodstream. Consultationwith a plastic surgeon or reconstructivehandsurgeon may be advisable.

Pressure Relief Procedure

To reduce the risk of seriousbodily injury, includingfluid injection and splashing in the eyesor on the skin, always follow this procedure whenever you stop spraying for more than10minutes, when shutting down, and before checking01 repairing any partofthesystem.

1.Engage the trigger safety latch.

2.Tum the sprayer off.

3.Disconnect the electrical supply.

4.Shut off the water supply.

5.Disengage the trigger safety latch and trigger the gunio relieve pressure, and then engage the trigger safety latch again.

6.Before long-term (overnight) storage, disconnect the water supply and disconnect the electricity.

Spray Gun Safety Devices

Be sure all gun safety devices are operating properly before each use.Do not remove ormodify any part of the gun; this can cause a malfunction and result in serious bodily injury.

SAFETY LATCH: Whenever you stop spraying for a moment, always set the gun Safety latchinthe engaged

or "safe"position, making the gun inoperative. Failureto properly set the safety latch can resultin accidental triggering of the gun.

SPRAY TIP SAFEPI: Use extreme caution when cleaning or changing spray tips. If a spray tip clogs while spraying, engage the gun safety latch immediately. ALWAYS follow the Pressure Rellet Procedure and then remove the spray tipto clean it.

Page 2
Image 2
Graco Inc 800-902, Serles A, 800-903, 800-904, 800-905, 720, 308-533, 710, 1020, 1010 manual Fluid Injection Hazard

1010, 1020, 710, 308-533, 720 specifications

Graco Inc. is a leading manufacturer known for its innovative solutions in the fields of fluid handling and spray equipment. Among its diverse product range, the models 800-905, 800-902, 800-904, 308-533, and 710 stand out for their unique features, advanced technologies, and notable characteristics, catering to a broad spectrum of industrial and commercial applications.

The Graco 800-905 is recognized for its robust construction and reliability. This high-performance unit is designed for heavy-duty applications, providing efficient fluid transfer and precise material delivery. Key features include a durable pressure pump, allowing for extended service life and reduced maintenance. The ergonomic design ensures ease of use, while the built-in safety mechanisms enhance operator protection during operation.

In the case of the Graco 800-902, this model emphasizes versatility and adaptability. It can handle a wide range of fluids, making it suitable for various industries, from automotive to manufacturing. The 800-902 features adjustable pressure settings, offering users the flexibility to switch between different tasks without compromising performance. Its compact design allows for easy transportation and setup, making it ideal for both stationary and mobile applications.

The Graco 800-904 takes efficiency to new heights with its innovative pump technology. It provides a consistent and smooth flow of materials, reducing waste and promoting a cleaner working environment. The model also incorporates an advanced filtration system, ensuring that impurities do not compromise fluid quality. This feature is particularly important in sectors where precision and quality are paramount, such as in the coatings and adhesives industry.

The Graco 308-533 focuses on enhancing user experience through intuitive controls and streamlined workflows. This unit is engineered for rapid deployment, allowing operators to quickly engage in their tasks. Additionally, its energy-efficient design not only reduces operational costs but also minimizes environmental impact, aligning with modern sustainability goals.

Finally, the Graco 710 showcases the brand’s commitment to technological advancement. This model features cutting-edge electronic controls that provide real-time monitoring of performance data, facilitating proactive maintenance and operational adjustments. Its user-friendly interface allows for easy navigation of settings and configurations, making it an ideal choice for professionals seeking precision and control.

In summary, Graco Inc.’s models 800-905, 800-902, 800-904, 308-533, and 710 exemplify the company’s dedication to quality, innovation, and efficiency. Each model provides unique features tailored to meet the diverse needs of various industries, reinforcing Graco's reputation as a trusted leader in fluid handling solutions.