Connect Alarm Input Equipment to the GXV3662

GXV3662 IP Camera

(PIR), smoke sensor or light sensor to it. The detectable signal voltage range for alarm-in is from 1.8V to 15 V NOTE: Please do not connect a device that has a signal voltage that is higher than 15V, this will damage the IP camera.

Internally, the Alarm-out uses relays as a switch (30VAC/2A); users can connect devices such as an alarm siren, alert lights or electric strike to this port. Under normal circumstances, the circuit is open. When there is an alarm event, the GXV3662 will close the circuit to trigger the alarm.

Connect Alarm Input Equipment to the GXV3662

Here are two sample connection diagrams. Connect the alarm equipment to the GXV3662 by following the diagram below.

Set up Alarm Actions

An alarm action is what the GXV3662 is going to do when an alarm is triggered during the