Greenheck Fan manual AX 113-400 6 Blades, Header

Models: AX

1 64
Download 64 pages 52.12 Kb
Page 48
Image 48

AX 113-400 6 Blades

 

 

Page Header

 

 

 

Impeller Diameter = 44.5 inches (1130 mm)

 

Outlet Velocity

ft/min = cfm / 10.80

Total

m/s = m³/s / 1.0

 

Pressure

Tip Speed

ft/min = rpm X 11.7

 

 

 

 

m/s = rpm X 3.55

 

 

92

 

88

91

93

88

90

 

92

 

88

 

92

 

Air density = 1.2 kg/m³

Volume

 

Air density = 0.075 lbs/ft³

 

 

 

Peak Absorbed Power [Bhp/kW (60 Hz), kW (50 Hz)]

Pitch Angle º

 

rpm

5

10

15

20

25

30

35

1170

(Bhp/kW)

3.78/2.82

6.23/4.65

9.00/6.72

12.2/9.11

16.0/12.0

20.7/15.4

26.6/19.8

870

(Bhp/kW)

1.55/1.16

2.56/1.91

3.70/2.76

5.02/3.74

6.60/4.92

8.51/6.35

10.9/8.15

1450

(kW)

5.37

8.84

12.8

17.3

22.8

29.4

37.8

950

(kW)

1.51

2.49

3.60

4.88

6.41

8.27

10.6

Sound Power A-Weighted [LwA] Sound Pressure [dBA]

Inlet Sound

rpm

LwA

dBA

1170

+6

-5.5

870

-

-11.5

1450

+13

+1.5

950

+2

-9.5

Performance shown is for installation Type B: Free inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances in the airstream. The AMCA Certified Ratings Seal applies to air performance ratings only.

Sound power level ratings are shown in decibels, referred to 10-12 watts calculated per AMCA Standard 301. Values shown are for inlet LwA sound power levels for 100%, 50% and 0% of peak pressure in Installation Type B: Free inlet, Ducted outlet. dBA sound pressure values are weighted with 11.5 dB attenuation for each octave band at 5 feet.