Greenheck Fan AX PerformancePage Header Manual Guide, How to use this performance manual

Models: AX

1 64
Download 64 pages 52.12 Kb
Page 3
Image 3

PerformancePage Header Manual Guide

How to use this performance manual

The performance pages contains information in metric and english units. These are color coded with motor power frequency and motor speed for easy and quick reference in finding air performance, power requirements, and sound information. See back cover for selection example.

1Model size and hub

 

diameter

AX 31-160 4 Blades

 

 

 

 

 

 

 

2

Total Pressure Axis

 

 

 

 

 

 

 

 

 

 

1

 

 

 

 

 

 

 

 

 

 

 

in Pascals (Pa) and

 

 

 

 

 

 

11

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Impeller Diameter = 12.25 inches (311 mm)

 

 

 

Inches Water Gauge

 

 

 

 

 

 

 

 

Outlet Velocity

ft/min = cfm / 0.82

 

 

 

(in. wg)

2

 

Total

 

 

 

 

m/s = m³/s / 0.08

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pressure

 

 

 

 

Tip Speed

 

 

 

3

Static Pressure

 

 

 

7

 

ft/min = rpm X 3.20

 

 

 

 

 

 

 

 

 

 

 

m/s = rpm X 0.98

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

- Lines of constant

 

 

 

 

 

 

 

 

65

 

 

 

 

3

 

static pressure

 

 

 

 

 

 

 

 

 

67

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

68

 

 

 

 

 

 

 

4

Color coded power

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8

 

 

 

 

 

frequency and motor

 

 

 

 

 

 

 

 

 

 

67

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

speed (rpm)/poles

 

 

 

 

 

 

 

 

 

 

66

 

 

 

5

Volume - Axis

 

 

 

 

 

 

68

 

 

 

 

 

68

 

 

displays two different

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

units of measure

 

 

 

 

 

 

 

 

 

 

 

67

 

 

 

for each power

 

 

 

 

 

 

 

 

 

 

 

6

 

 

 

frequency and motor

 

 

 

 

 

 

 

 

69

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

speed.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

Blade pitch -

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Shown in 5 degree

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

increments, integral

 

 

 

 

 

 

 

 

 

 

 

 

 

5

 

pitches are available

4

 

 

 

 

 

 

 

 

 

 

 

 

 

between the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

displayed limits.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7

Sound power (LwA)

Air density = 0.075 lbs/ft³

 

 

 

 

 

Volume

 

 

 

 

- Color coded sound

 

 

 

 

 

 

 

 

 

 

Air density = 1.2 kg/m³

 

 

 

 

 

 

 

 

 

 

 

power level levels

9

 

 

 

 

 

 

 

 

 

 

10

 

 

 

are displayed as

 

 

 

 

 

 

 

 

 

 

 

 

 

a percentage of

 

 

 

 

 

 

 

 

 

 

 

Sound Power A-Weighted [LwA]

 

Peak Absorbed Power [Bhp/kW (60 Hz), kW (50 Hz)]

 

 

 

 

 

Sound Pressure [dBA]

 

 

peak power; 100%,

 

 

 

 

 

Pitch Angle º

 

 

 

 

Inlet Sound

 

 

 

rpm

 

5

10

15

20

 

25

30

35

rpm

LwA

dBA

 

50% and 0%. Use

3500 (Bhp/kW)

0.19/0.14

0.30/0.22

0.43/0.32

0.56/0.42

0.71/0.53

0.88/0.66

1.07/0.80

3500

+20

+8.5

 

1770 (Bhp/kW)

0.03/0.02

0.04/0.03

0.06/0.04

0.07/0.05

0.09/0.07

0.11/0.09

0.14/0.10

1770

-

-11.5

 

corrections in the

2900 (kW)

 

0.08

0.13

0.18

0.24

0.30

0.37

0.45

2900

+13

+1.5

 

sound power table to

1450 (kW)

 

0.01

0.02

0.02

0.03

0.04

0.05

0.06

1450

-5

-16.5

 

Performance shown is for installation Type B: Free inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances in the airstream. The AMCA Certified Ratings

 

find corresponding

Seal applies to air performance ratings only.

 

 

 

 

 

 

 

 

 

 

Sound power level ratings are shown in decibels, referred to 10-12 watts calculated per AMCA Standard 301. Values shown are for inlet LwA sound power levels for 100%, 50% and

 

LwA and dBA levels

0% of peak pressure in Installation Type B: Free inlet, Ducted outlet. dBA sound pressure values are weighted with 11.5 dB attenuation for each octave band at 5 feet.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

for a specific power

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

frequency and motor speed.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8Total Efficiency curves - Curves show total efficiency levels at different performance points. Those curves do not reflect static efficiency levels.

9Peak Absorbed Power table - Table displays the maximum power required by pitch angle and motor rpm. Values provided are in brake horse power and kilowatts.