Installation

NOTE: If you have a Back Supply

Plenum, this must be installed beforeFig. 1 the hood. Please see page 8 now.

Prior to installation, check with local authorities having jurisdiction on clearances to combustible surfaces.

With the hood still inside its packing crate, position the unit beneath its installation location.

Carefully remove the packing crate. Place some protective material on

the floor next to the crate to avoid

damaging the hood as it is tipped on its side (Fig. 1). Tip the hood carefully onto the protective material. If you have filler panels, see Fig. 2 below. If you have integral filler panels, no additional installation is needed.

Hood Installation Overview

If a Back Supply Plenum is provided, install first. Before raising hood, insert 1/2 in. (12.7 mm) diameter threaded rod (by others) into hanger brackets on hood top. Check the engineering drawings or UL label located on the inside of the hood for proper hood height above finished floor. Install filler panels if needed. Raise and hang hood from adequate roof or ceiling supports and secure mounting flange to the wall using lag bolts, or fasten to the Back Supply Plenum if provided. All hanger brackets must be used and the hood must be properly supported while lifting to prevent damage or distortion to the hood. The hood must be hung level to operate properly. After hood is secured, make the exhaust duct connections. The fire system distributer must be contacted at this time. After the fire system has been installed, mount the enclosures, then the supply plenums. If a Horizontal Supply Plenum is provided, it should be installed according to the external supply plenum installation section found on page 7. The hood and accessories are now installed. Finally, make the electrical connections from switches to fans and complete the fire system circuits as required by the job specification.

Rear Filler Panel Installation Instructions

Rear filler panels may be shipped loose for field installaton or are integral to the hood. If fillers are integral to hood, skip this section.

1.Uncrate the hood and lay it on the floor with protective material between the hood and the floor.

2.Bolt the filler panels together with 5/16 in. bolts from the hardware package.

3.Position the filler panels on the hood, and tack- weld them to the hood back.

4.To allow for ease of cleaning, caulk the external seams with NSF Approved silicone caulk

(GE SCS1009, or its equivalent). The caulk is not provided.

Hood Top

Hood Back

Bottom Filler Panel

5/16 x 3/4 in. (8 x 19 mm) Bolts with Washers and Nuts

Hood Front

Backshelf

Fig. 2

Hood Front

Proximity Hood

®

Page 4
Image 4
Greenheck Fan PN 458294 manual Hood Installation Overview, Rear Filler Panel Installation Instructions

PN 458294 specifications

Greenheck Fan PN 458294 is a prominent product in the HVAC industry, designed to deliver high performance, efficiency, and reliability in various applications. This unit is widely recognized for its ability to optimize airflow while minimizing energy consumption, a feature that is becoming increasingly vital in current energy-conscious markets.

One of the key features of the Greenheck Fan PN 458294 is its robust construction. Built with durable materials, this fan is engineered to withstand harsh environmental conditions, making it suitable for both indoor and outdoor installations. The corrosion-resistant finish further enhances its resilience, ensuring a longer lifespan and reduced maintenance costs.

The fan is equipped with advanced aerodynamic designs that improve its airflow performance. This design focus not only maximizes the fan's efficiency but also provides quieter operation, which is a crucial factor in sensitive environments such as offices, schools, and hospitals. The noise reduction technology integrated into the unit helps maintain a comfortable atmosphere while keeping operational disturbances to a minimum.

In terms of technology, the Greenheck Fan PN 458294 features state-of-the-art motor technology that offers variable speed control. This capability allows users to adjust the fan's operation according to specific needs, enhancing energy efficiency while ensuring optimal airflow. The internally mounted motor and belt drive system contribute to reduced vibration and increased stability, further lowering wear and tear over time.

This fan also incorporates innovative control options, allowing for easy integration into existing building management systems. This smart technology enables users to monitor and adjust performance remotely, ensuring maximum efficiency and adaptability to changing operational demands.

Another noteworthy characteristic of the Greenheck Fan PN 458294 is its versatility. It can be utilized in a variety of applications, including industrial ventilation, commercial exhaust, and air supply systems. The wide range of available configurations and accessory options makes it an ideal choice for meeting diverse project requirements.

In conclusion, the Greenheck Fan PN 458294 stands out in the HVAC market due to its combination of robust construction, advanced aerodynamic design, innovative motor technology, and versatile application capabilities. As energy efficiency continues to be a priority in building design, this fan offers a reliable solution for maintaining optimal airflow while minimizing environmental impact.