Grindmaster 2450, 1750 installation manual cont’d, Troubleshooting Guide, Page

Models: 1750 2450

1 28
Download 28 pages 55.22 Kb
Page 16
Image 16

Troubleshooting Guide

 

(cont’d)

 

 

 

 

 

 

 

 

 

 

 

 

Problem

 

 

Possible Cause

 

Solution

 

 

Steam too watery.

 

Faulty float switch.

If float switch is at correct level

 

 

(continued from previous page)

 

 

 

 

(lines are aligned on tube and

 

 

 

 

 

 

 

fitting) and red light stays on

 

 

 

 

 

 

 

continuously, then replace float

 

 

 

 

 

 

 

switch. Note: Disconnect machine

 

 

 

 

 

 

 

from power before replacing or

 

 

 

 

 

 

 

adjusting.

 

 

 

 

Leaking two-way inlet solenoid.

If red autofill light is off, check if

 

 

 

 

 

 

 

two-way solenoid is leaking. Note:

 

 

 

 

 

 

 

Machine must have 0 pressure

 

 

 

 

 

 

 

before disconnecting the fitting

 

 

 

 

 

 

 

past the two-way solenoid valve.

 

 

 

 

 

 

 

If fitting is leaking water, then

 

 

 

 

 

 

 

replace the two-way solenoid. It

 

 

 

 

 

 

 

should normally be closed.

 

 

 

 

 

 

 

 

 

 

No pressure on gauge.

 

No power to machine.

Check to make sure machine is

 

 

 

 

 

 

 

turned on and plugged in.

 

 

 

 

 

 

Check outlet has power with lamp

 

 

 

 

 

 

 

or radio.

 

 

 

 

 

 

Check main circuit breaker.

 

 

 

 

Unplug machine then check for

Reconnect loose wires.

 

 

 

 

 

loose wires on main switch,

 

 

 

 

 

 

 

pressure control and heaters.

 

 

 

 

 

 

If heater light is not on and there

Replace pressure control if faulty

 

 

 

 

 

is electricity to the pressure

 

and check machine.

 

 

 

 

 

control, control may be faulty.

 

 

 

 

 

 

If heater light is on and the

Replace main heater if faulty and

 

 

 

 

 

group heads are hot, heater may

 

check for cause of heater failure.

 

 

 

 

 

be faulty.

 

 

 

 

 

 

If heater light is not on and there

Replace main power switch if

 

 

 

 

 

is no electricity to pressure

 

faulty and check machine.

 

 

 

 

 

control, main power switch may

 

 

 

 

 

 

 

be faulty.

 

 

 

 

 

 

 

 

 

 

 

 

Machine will not operate.

 

No power to machine.

Check to make sure machine is

 

 

 

 

 

 

 

turned on and plugged in.

 

 

 

 

 

 

Check to verify outlet has power

 

 

 

 

 

 

 

with lamp or radio.

 

 

 

 

 

 

Check main circuit breaker.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

If you still need help, call an authorized dealer in your area or Grindmaster Corporation’s Technical Service Department. You can reach Technical Service at (800) 695-4500 (USA & Canada only) or (502) 425-4776 Monday-Friday, 8:00 AM - 8:00 PM Eastern Standard Time. Please have the model and serial number ready so that accurate information can be given. Prior authorization must be obtained from Grindmaster Corporation’s Technical Service Department for all warranty claims.

Page 15

Espressimo 2450 & 1750 Espresso Cappuccino Machines

Page 16
Image 16
Grindmaster 2450, 1750 installation manual cont’d, Troubleshooting Guide, Page