| Troubleshooting Guide | 
 | (cont’d) | 
 | 
 | 
 | ||
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
| 
 | Problem | 
 | 
 | Possible Cause | 
 | Solution | 
 | 
| 
 | Steam too watery. | 
 | • | Faulty float switch. | • | If float switch is at correct level | 
 | 
| 
 | (continued from previous page) | 
 | 
 | 
 | 
 | (lines are aligned on tube and | 
 | 
| 
 | 
 | 
 | 
 | 
 | 
 | fitting) and red light stays on | 
 | 
| 
 | 
 | 
 | 
 | 
 | 
 | continuously, then replace float | 
 | 
| 
 | 
 | 
 | 
 | 
 | 
 | switch. Note: Disconnect machine | 
 | 
| 
 | 
 | 
 | 
 | 
 | 
 | from power before replacing or | 
 | 
| 
 | 
 | 
 | 
 | 
 | 
 | adjusting. | 
 | 
| 
 | 
 | 
 | • | Leaking  | • | If red autofill light is off, check if | 
 | 
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | |
| 
 | 
 | 
 | 
 | 
 | 
 | Machine must have 0 pressure | 
 | 
| 
 | 
 | 
 | 
 | 
 | 
 | before disconnecting the fitting | 
 | 
| 
 | 
 | 
 | 
 | 
 | 
 | past the  | 
 | 
| 
 | 
 | 
 | 
 | 
 | 
 | If fitting is leaking water, then | 
 | 
| 
 | 
 | 
 | 
 | 
 | 
 | replace the  | 
 | 
| 
 | 
 | 
 | 
 | 
 | 
 | should normally be closed. | 
 | 
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
| 
 | No pressure on gauge. | 
 | • | No power to machine. | • | Check to make sure machine is | 
 | 
| 
 | 
 | 
 | 
 | 
 | 
 | turned on and plugged in. | 
 | 
| 
 | 
 | 
 | 
 | 
 | • | Check outlet has power with lamp | 
 | 
| 
 | 
 | 
 | 
 | 
 | 
 | or radio. | 
 | 
| 
 | 
 | 
 | 
 | 
 | • | Check main circuit breaker. | 
 | 
| 
 | 
 | 
 | • | Unplug machine then check for | • | Reconnect loose wires. | 
 | 
| 
 | 
 | 
 | 
 | loose wires on main switch, | 
 | 
 | 
 | 
| 
 | 
 | 
 | 
 | pressure control and heaters. | 
 | 
 | 
 | 
| 
 | 
 | 
 | • | If heater light is not on and there | • | Replace pressure control if faulty | 
 | 
| 
 | 
 | 
 | 
 | is electricity to the pressure | 
 | and check machine. | 
 | 
| 
 | 
 | 
 | 
 | control, control may be faulty. | 
 | 
 | 
 | 
| 
 | 
 | 
 | • | If heater light is on and the | • | Replace main heater if faulty and | 
 | 
| 
 | 
 | 
 | 
 | group heads are hot, heater may | 
 | check for cause of heater failure. | 
 | 
| 
 | 
 | 
 | 
 | be faulty. | 
 | 
 | 
 | 
| 
 | 
 | 
 | • | If heater light is not on and there | • | Replace main power switch if | 
 | 
| 
 | 
 | 
 | 
 | is no electricity to pressure | 
 | faulty and check machine. | 
 | 
| 
 | 
 | 
 | 
 | control, main power switch may | 
 | 
 | 
 | 
| 
 | 
 | 
 | 
 | be faulty. | 
 | 
 | 
 | 
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
| 
 | Machine will not operate. | 
 | • | No power to machine. | • | Check to make sure machine is | 
 | 
| 
 | 
 | 
 | 
 | 
 | 
 | turned on and plugged in. | 
 | 
| 
 | 
 | 
 | 
 | 
 | • | Check to verify outlet has power | 
 | 
| 
 | 
 | 
 | 
 | 
 | 
 | with lamp or radio. | 
 | 
| 
 | 
 | 
 | 
 | 
 | • | Check main circuit breaker. | 
 | 
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
If you still need help, call an authorized dealer in your area or Grindmaster Corporation’s Technical Service Department. You can reach Technical Service at (800) 
| Page 15 | Espressimo 2450 & 1750 Espresso Cappuccino Machines | 