Grindmaster 67710E service manual To adjust the rate cont, Fill Rate Adjustment, Fill Rate Valve

Models: 67710E

1 19
Download 19 pages 39 Kb
Page 14
Image 14
To adjust the rate (cont)

To adjust the rate (cont)

The level in the liner should be one inch below the line where the liner ring attaches to the liner wall.

Re-adjust until the level is correct.

Fill Rate Adjustment

The fill rate depends on the water line pressure and the

 

opening of the FAST FILL VALVE, see figure 8. If the urn

 

does not refill as fast as it uses water during a brew cycle, you

 

may adjust the fill rate. If you adjust for maximum fill rate and

 

the level still cannot keep up, either the pressure is too low or

Figure 8, Fill Rate Valve

the fill system may have a clog. See Troubleshooting.

 

To Adjust the Fill Rate:

Remove the control access cover.

Locate the needle valve labeled, FAST FILL VALVE.

Open the valve a few turns.

Brew water into both liners simultaneously. Watch the FILLING indicator.

If the light cycles on and off, the rate is fast enough.

If the FILLING light stays on, the rate is too slow. Re-adjust.

 

 

American Metal Ware 67710E Coffee Urn