WARNING - Read and follow installation instructions before plugging or wiring in machine to electrical circuit. Warranty will be void if unit is connected to any voltage other than that listed on the name plate.
FILL BREWER TANK WITH WATER BEFORE CONNECTION TO POWER SUPPLY
WATER CONNECTION
The following is required for water
1)A quick disconnect water connection or enough coiled tubing so the machine can be moved for cleaning underneath. (required for NSF approved water
2)A 1/4" male flare adapter is provided to be attached by the installer to the back of the machine for
3)Installation to a water filter system is required to prevent lime and scale build up in the machine.
4)Water pipe connections and fixtures directly connected to potable water supply shall be sized, installed, and maintained in accordance with Federal, State, and Local codes. (required for NSF approved water
5)Equipment is to be installed with adequate backflow protection to comply with applicable Federal, State, and local codes. (required for NSF approved water
Minimum water pressure to the machine: 30 psi (2.0 bar)
Maximum water pressure to the machine: 80 psi (5.6 bar)
INSTALLATION INSTRUCTIONS
1)Place the decanter under brew basket, raise top evaporation cover and pour three decanters of water through the top
2)Brewer is shipped with thermostat turned on, (full clockwise position). Plug brewer into a dedicated, grounded 120V/15A circuit (230V/15A circuit for E models).
3)Allow
4)After water has reached brewing temperature (thermostat will click off, heating noise will stop and green ready light will be on) pour 1 decanter (60 oz./1.8L) of water through
5)Pour 1 decanter of water through
6)In higher altitude locations (5,000 feet/1,500m above sea level) the thermostat may have to be adjusted lower to prevent boiling.
Page 4 | Auto Series Brewer Manual |
|
|