SECTION 4: OPERATIONS

Operation Safety

Damage to your eyes, lungs, and ears could result from using this machine without proper protective gear. Always wear safety

Power Controls

It is vital that you become familiar with the power controls before operating the Model G0463. Three separate switches control the power on the mill/drill (see Figure 10).

glasses, a respirator, and hearing protection when operating this machine.

1

2

3

4 5

6

Loose hair and cloth-

ing could get caught in

machinery and cause seri-

ous personal injury. Keep

loose clothing and long

hair away from moving machinery.

NOTICE

If you have never used this type of machine or equipment before, WE STRONGLY REC- OMMEND that you read books, trade maga- zines, or get formal training before begin- ning any projects. Regardless of the con- tent in this section, Grizzly Industrial will not be held liable for accidents caused by lack of training.

7

Figure 10. Control panel components.

1.EMERGENCY STOP Button: Immediately disconnects power to the system. Once pressed, this button must be twisted until it pops out to return power to the switches. The FAULT INDICATOR Light will turn on and the MAIN POWER Switch needs to be turned OFF.

2.FAULT INDICATOR Light: Indicates a cir- cuit interruption due to a switch being out of proper position. Turn all switches OFF when lit.

3.POWER INDICATOR Light: Shines when the system power is ON.

4.Fuse Socket: Houses a 10 Amp system fuse.

-18-

G0463 Small Mill/Drill

Page 20
Image 20
Grizzly G0463 owner manual Operations, Operation Safety, Power Controls