SECTION 2: CIRCUIT REQUIREMENTS

Power Connection

Serious personal injury could occur if you connect the machine to the power source before you have completed the set up pro- cess. DO NOT connect the machine to the power source until instructed to do so.

Amperage Draw

The motor for your machine may draw the follow- ing amps at maximum load.

G0596 at 110V Single-Phase

14

Amps

G0597 at 220V Single-Phase

8.5

Amps

G0598 at 220V

Single-Phase

12

Amps

G0599 at 220V

3-Phase

10

Amps

Power Supply Circuit Requirements

The power supply circuit for your machine MUST be grounded and rated for the amperage given below. Never replace a circuit breaker on an exist- ing circuit with one of higher amperage without consulting a qualified electrician to ensure compli- ance with wiring codes. If you are unsure about the wiring codes in your area or you plan to connect your machine to a shared circuit, con- sult a qualified electrician.

G0596

Power Source

110V

Single-Phase

G0596

Minimum Circuit Size

20 Amps

G0597

Power Source

220V

Single-Phase

G0597

Minimum Circuit Size

15 Amps

G0598

Power Source

220V

Single-Phase

G0598

Minimum Circuit Size

15 Amps

G0599

Power Source

220V 3-Phase

G0599

Minimum Circuit Size

15 Amps

Plug Type

With the exception of the G0596, the cord set enclosed does not have a plug as the style of plug you require will depend upon the type of service you currently have or plan to install. We recom- mend using the following plugs for your machine on a dedicated circuit only (see Figures 1–??for examples):

G0597 at 220V

NEMA 6-15 Plug

G0598 at 220V

NEMA 6-15 Plug

G0599 at 220V 3-Phase..

NEMA 15-15R Plug or

..220V Locking Shut-Off Switch (recommended)

Figure 1. NEMA 6-15 plug and receptacle.

<gdjcYZY

DjiaZi7dm

8jggZci

8Vggn^c\

7aVYZh

<gdjcY^c\E^c

Figure 2. NEMA 15-15R plug and receptacle.

Model G0596-99 (Mfg. since 3/06)

-7-

Page 9
Image 9
Grizzly G0596-99 owner manual Circuit Requirements, Power Connection