Be sure that you extend the bare copper wire down all branches of the system. Do not forget to connect the wires to each other with wire nuts when two branches meet at a “Y” or “T” connec- tion.

Ensure that the entire system is grounded. If using plastic blast gates to direct air flow, the grounding wire must be jumped (Figure 12) around the blast gate without interruption to the grounding system.

Plastic Blast Gate

Copper Ground Wire

Metal Duct

 

Figure 12. Ground jumper wire when using

plastic blast gates and metal duct.

We also recommend wrapping the outside of all plastic ducts with bare copper wire to ground the outside of the system against static electrical build up. Wire connections at Y’s and T’s should be made with wire nuts.

Attach the bare ground wire to each stationary woodworking machine and attach the dust collec- tor frame with a ground screw as shown in Figure

13.Ensure that each machine is continuously grounded to the grounding terminal in your elec- tric service panel.

Ground Screw

Flex-Hose

External Ground Wire

Internal Ground Wire

Figure 13. Flex-hose grounded to machine.

G1028Z/G1029 Dust Collector

-17-

Page 19
Image 19