SECTION 2: CIRCUIT REQUIREMENTS

G1028Z Wiring

G1029 Wiring

The G1028Z Dust Collector is pre-wired for 110V, but can be rewired for 220V. Refer to the wiring diagram included with this manual for instruction. Do not attempt to rewire the motor if the diagram is missing. Contact the appropriate service center for more information.

A plug is not provided with the G1028Z. It will be necessary to purchase a standard 110V plug from your local hardware store. If you are rewiring for 220V, see Figure 1 for the recommended 220V receptacle.

Circuit Breaker: The 112 H.P. motor will draw roughly 18 amps at 110V or 9 amps at 220V. We recommend a using 20 amp circuit breaker for 110V or 220V operation. Circuit breakers rated higher will not adequately protect the circuit. If you are using a fuse, we recommend a 30 amp slow blow for 110V or 220V operation. Fuses rated higher will not adequately protect the circuit.

The G1029 Dust Collector is pre-wired for 220V.

A plug is not provided with the G1029. Refer to Figure 1 for recommended 220V receptacle.

Circuit Breaker: The 2 H.P. motor will draw roughly 12 amps @ 220V. We recommend using a 20 amp circuit breaker. Circuit breakers rated higher will not adequately protect the motor. If you are using a fuse, we recommend 30 amp slow blow 220V service. Fuses rated higher will not adequately protect the motor.

Figure 1. Recommended 220V receptacle.