Compressed Air

System

The Model H6144 is designed to be oper- ated at 60-100 PSI using clean, dry, regu- lated, compressed air. DO NOT exceed the maximum operating pressure for your model.

Before using your new nailer, install a

14" NPT male quick connect fitting (not included) on the nailer and a matching

14" NPT female fitting (not included) on the air hose. Regulate the air pressure on your air compressor to the minimum PSI for your model.

An in-line filter/lubricator/regulator unit, shown in Figure 2, can be installed and should be located as close to the H6144 as possible.

This filter/lubricator/regulator unit will protect your tool from damaging water build-up, allow you to adjust and maintain constant air pressure to your tool, and save you the inconvenience of having to manually lubricate your tool every time you use it.

Exceeding the maximum permissible operating pressure may cause the nailer to explode, blowing metal frag- ments in all directions. To protect yourself from serious personal injury, DO NOT allow your air compressor to exceed the recommended pressure when connected to this nailer!

Check the current Grizzly catalog for avail- ability of this unit. If you plan on install- ing a filter/lubricator/regulator unit in your compressed air system, always follow the connection instructions that come with the unit.

Quick

Quick

 

Filter

Connector

Connector Oiler

 

Nailer

 

 

 

Quick

 

 

 

Coupler

 

Quick Regulator

 

Air Hose

 

Coupler

 

 

 

 

Air

Compressor

Figure 2 . Filter/Lubricator/Regulator Unit.