MODEL T24101 |
3 HP 230V |
MAGNETIC SWITCH |
INSTRUCTIONS |
Electrocution or fire could occur if this switch is not installed by an electrician or qualified service per- sonnel!
230Volt
Contactor TECO
COLOR KEY
BLACK Bk
GREEN Gn
RED Rd
YELLOW
Thermal Overload Relay
TECO RHU-10K1
1L1 3L2 5L3 13NO
TECO
CU- 16
2T1 4T2 6T3 14NO
TRIP IND.
M
| O | R | |
TEST |
| A | |
OFF | RESET | ||
| |||
97 NO | 98 NO 95 NC | 96 NC |
NO 53
ON
54 NO
Ground
Figure 1. Model T24101 magnetic
switch.
(21-25A)
2T1 4T2 6T3
3 HP 230V Motor |
OPERATION: When pushed, the green ON button on the outside cover of the magnetic switch energizes a magnetic coil, which pulls the contactor closed. The main current then passes through the contactor and thermal overload relay to the motor. The red OFF button breaks the magnetic field, which opens the contactor and disconnects the current to the motor. A motor overload or an interruption of the power supply will also break the magnetic field and release the contactor and disconnect current to the motor. The motor will not
Copyright © october, 2011 By Grizzly Industrial, Inc.
Warning: No portion of this manual may be reproduced in any shape
Or form without the written approval of Grizzly Industrial, inc.
#ST14414 printed in TAIWAN