TROUBLESHOOTING
OSD Message
The messages as described below may appear on the screen at power ON. Take the appropriate measures when such a message appears.
Table 8. OSD Messages
Message | Contents | |
|
| |
| The message shown at left appears after the lamp has | |
CHANGE THE LAMP | been used for more than 1700 hours. | |
The lamp is approaching the end of its life. | ||
AFTER REPLACING LAMP, | ||
Power is switched OFF automatically when the lamp | ||
RESET THE LAMP TIME. | ||
reaches the end of its life. Prepare a new lamp for | ||
*1) | ||
| installation. | |
| Always reset the lamp timer after replacing the lamp. | |
|
| |
CHANGE THE LAMP | The lamp will reach the end of its life in ** hours. | |
AFTER REPLACING LAMP, | ||
RESET THE LAMP TIME. | Power will be switched OFF automatically in ** hours. | |
THE POWER WILL TURN OFF | Replace the lamp as shown in P.17 “Lamp”. | |
AFTER ** hr. | Always reset the lamp timer after replacing the lamp. | |
*1) |
| |
|
| |
CHANGE THE LAMP | The lamp has reached the end of its life. Power will be | |
AFTER REPLACING LAMP, | ||
switched OFF in a few minutes. | ||
RESET THE LAMP TIME. | ||
Switch power OFF immediately and replace the lamp as | ||
THE POWER WILL | ||
shown in P.17 “Lamp”. | ||
TURN OFF | ||
Always reset the lamp timer after replacing the lamp. | ||
AFTER 0 hr. | ||
| ||
|
| |
NO INPUT IS DETECTED | No input signal found. | |
ON *** | Check signal input connections and signal sources. | |
|
| |
| The horizontal or vertical frequency of the input signal is | |
SYNC IS OUT OF RANGE | not within the specified range. | |
ON *** | Check the specifications of the equipment and the signal | |
| source. | |
|
| |
| The internal temperature has risen. | |
| Switch power OFF, and wait 20 minutes until the | |
| equipment cools. | |
CHECK THE AIR FLOW | Check the following and Switch power ON again. | |
| • Are the ventilation openings blocked? | |
| • Is the air filter dirty? | |
| • Is the ambient temperature in excess of 35°C? | |
|
|
*1) This message is cleared automatically after approximately three minutes, and appears every time power is switched ON.