Section 4 — Maintenance

Liquid-cooled 30 kW Generators

‹4.5.12 SPARK PLUGS

Reset the spark plug gap or replace the spark plugs as necessary. See Section 6.

1.Clean the area around the base of the spark plugs to keep dirt and debris out of the engine. Clean by scraping or washing using a wire brush and commercial solvent. Do not blast the spark plugs to clean.

2.Remove the spark plugs and check the condition. Replace the spark plugs if worn or if reuse is questionable. See the “Service Schedule,” Section 6, for recommended inspection.

3.Check the spark plug gap using a wire feeler gauge. Adjust the gap to 1.06-1.16 mm (0.042- 0.046 inch) by carefully bending the ground elec- trode (Figure 4.4).

Figure 4.4 – Setting the Spark Plug Gap

SET PLUG GAP AT 1.06-1.16 mm

(0.042-0.046 inch)

‹4.5.13 COOLANT CHANGE

Every year, have Authorized Service Facility drain, flush and refill the cooling system. See SPECIFICATIONS (Section 1.10) for cooling system recommendations.

Finally, have the insulation resistance of stator and rotor windings checked. If insulation resistances are excessively low, the generator may require drying.

‹4.6.2 BATTERY

All lead-acid storage batteries discharge when not in use. Refer to specific instructions and warnings that accompany the battery. If such information is not available, observe the following precautions when handling a battery:

DO NOT use jumper cables and a booster battery to crank or start the generator engine.

DO NOT recharge a weak battery while it is installed in the generator. Remove battery from generator and recharge in a well-ventilated area, away from fuel vapors, sparks, heat or flames.

Battery electrolyte fluid is an extremely caustic sulfuric solution that can cause severe burns. DO NOT permit fluid to contact eyes, skin, clothing, painted surfaces, wiring insulation, etc. If any bat- tery fluid is spilled, flush the affected area with clear water immediately.

Always wear safety glasses, rubber apron and gloves when handling a battery.

Batteries give off explosive hydrogen gas while charging. The gas can form an explosive mixture around the battery for several hours after charging. Any spark, heat or flames can ignite the gas and cause an explosion which can shatter the battery, causing blindness or other serious injury.

‹4.6.3 BATTERY MAINTENANCE

The battery should be inspected per the “Service Schedule,” Section 6. The following procedure should be followed for inspection:

4.6MISCELLANEOUS MAINTENANCE

‹4.6.1 CLEANING THE GENERATOR

Keep the generator as clean and as dry as possible. Dirt and moisture that accumulates on internal gen- erator windings have an adverse effect on insulation resistance.

Periodically clean generator exterior surfaces. A soft brush may be used to loosen caked on dirt. Use a vacuum system or dry, low pressure air to remove any accumulations of dirt. The generator is housed inside an all-weather enclosure, clean the enclosure with a soft, damp cloth or sponge and water.

Once each year, have the generator cleaned and inspected by an Authorized Service Dealer. That dealer will use dry, low pressure air to clean internal windings. Parts inside the control console should be cleaned and inspected at this time as well.

1.Inspect the battery posts and cables for tightness and corrosion. Tighten and clean as necessary.

2.Check the battery fluid level of unsealed batteries and, if necessary, fill with DISTILLED WATER ONLY. DO NOT USE TAP WATER IN BATTER- IES.

3.Have the state of charge and condition checked. This should be done with an automotive-type bat- tery hydrometer.

18

Page 20
Image 20
Guardian Technologies 004988-4 owner manual Miscellaneous Maintenance, ‹ 4.5.13 Coolant Change, ‹ 4.6.3 Battery Maintenance

004988-4 specifications

Guardian Technologies 004988-4 is a cutting-edge air purifier designed to create a cleaner and healthier indoor environment. With increasing concerns about air quality in our homes and workplaces, this innovative device provides an effective solution to combat airborne pollutants and allergens.

One of the standout features of the Guardian Technologies 004988-4 is its powerful 4-in-1 filtration system. This system includes a pre-filter that captures larger particles like dust and pet hair, a true HEPA filter that traps 99.97% of particles as small as 0.3 microns, an activated carbon filter that helps reduce odors, and a UV-C light that targets bacteria and viruses. This comprehensive filtration method ensures that the air you breathe is free from harmful contaminants.

Another important characteristic of the Guardian Technologies 004988-4 is its large coverage area. This air purifier is capable of effectively purifying air in rooms up to 300 square feet, making it suitable for bedrooms, living rooms, and office spaces. Its compact and modern design allows it to blend seamlessly with various interior styles, while its lightweight construction makes it easy to move from one room to another.

Additionally, the Guardian Technologies 004988-4 features a quiet operation mode, ensuring that it can run continuously without disrupting daily activities. It also comes equipped with multiple fan speeds, allowing users to customize the airflow based on their preferences and air quality needs. The unit is designed for user-friendly operation, with simple controls that make it easy to switch between modes and adjust settings.

Energy efficiency is another highlight of the Guardian Technologies 004988-4. It is constructed to consume low energy while maintaining high performance, making it an eco-friendly choice for air purification.

In summary, the Guardian Technologies 004988-4 offers a robust combination of features, including a 4-in-1 filtration system, wide coverage area, quiet operation, and energy efficiency. These characteristics make it a reliable and effective air purifying solution that contributes to a healthier indoor environment, promoting overall well-being for users and their families.