5.Wrap the foam precleaner in a clean cloth and gently squeeze it dry.

6.Saturate the foam precleaner in clean engine oil. Gently squeeze it in a clean cloth to remove excess oil and to distribute oil (DO NOT TWIST).

7.Install the foam precleaner into the cover, fol- lowed by the paper filter.

8.Install the cover, foam precleaner and paper fil- ter.

9.Tighten the two screws to retain the filter in place.

Figure 3.2 – Engine Air Cleaner

￿￿￿￿￿

￿￿￿￿￿￿￿￿￿￿

￿￿￿￿

￿￿￿￿￿￿￿￿￿￿

￿￿￿￿￿￿￿￿￿￿￿

￿￿￿￿￿

￿￿￿￿￿￿

‹3.3.2 CLEANING OR REPLACING THE PAPER FILTER

Once each year or every 100 hours of operation (whichever comes first), clean or replace the paper filter. The new replacement filter must be flame retardant. Service the paper filter more frequently if operating the generator in extremely dusty or dirty conditions. Use the following procedure (Figure 3.2):

1.Follow steps 1-3 in the "Cleaning the Foam Precleaner" section; service the foam precleaner if necessary.

2.Remove the paper filter.

3.Clean the air filter by tapping it gently on a solid surface. If the filter is too dirty, replace it with a new one. Dispose of the old filter properly.

4.Clean the air cleaner cover then reassemble following steps 7-9 in the "Cleaning the Foam Precleaner" section.

3.4CLEAN AIR INTAKE

Clean all foreign material from the air intake (Figure 3.3) at least once every 100 hours of operation. Clean more often if necessary.

Inspect the area around the generator exhaust muf- fler periodically and remove all grass, leaves, dirt, etc., from this area.

Recreational Vehicle Generator

Figure 3.3 – Cleaning Air Intake

3.5CHECKING THE ENGINE

SPARK PLUG

Clean the spark plug and reset the spark plug gap every 100 hours of operation.

1.Clean the area around the base of the spark plug to keep dirt and debris out of the engine. Clean by scraping or washing using a wire brush and commercial solvent. Do not blast the spark plug to clean.

2.Remove the spark plug and check the condition. Replace the spark plug if worn or if reuse is ques- tionable.

3.Check the spark plug gap using a wire feeler gauge. Adjust the gap to 0.030 inch (0.76 mm) by carefully bending the ground electrode (Figure 3.4).

Sparking can occur if the wire terminal does not fit firmly on the spark plug terminal end. If nec- essary, re-form the wire terminal to obtain a tight fit.

Figure 3.4 – Setting the Spark Plug Gap

13

Page 15
Image 15
Guardian Technologies 04164-3, 02010-2 owner manual Clean AIR Intake, Checking the Engine Spark Plug

04164-3, 02010-2 specifications

Guardian Technologies is proud to present the innovative 02010-2,04164-3 model, a standout product in its line of advanced air quality solutions specifically designed for modern homes. This cutting-edge air purifier is engineered to enhance indoor air quality, making it essential for those who prioritize a clean living environment.

One of the main features of the Guardian Technologies 02010-2,04164-3 is its powerful three-stage filtration system. This includes a pre-filter, a true HEPA filter, and an activated carbon filter, which work synergistically to capture a wide range of airborne pollutants. The pre-filter traps larger particles such as dust and pet hair, while the HEPA filter is capable of capturing 99.97% of allergens as small as 0.3 microns, including pollen, smoke, and mold spores. The activated carbon filter effectively reduces odors from pets, cooking, and smoke, providing a fresher living space.

In addition to its robust filtration capabilities, the 02010-2,04164-3 is equipped with Guardian Technologies' proprietary UVC light technology. This feature helps to further reduce airborne bacteria and viruses, giving users added peace of mind, especially in today’s health-conscious world. The UVC light works in conjunction with the filtration system to ensure a comprehensive level of air purification.

Another notable characteristic of this model is its compact and stylish design, making it suitable for any room in your home, whether it be the living room, bedroom, or office. Its lightweight construction allows for easy portability, letting users move it as needed for maximum efficiency.

The Guardian Technologies 02010-2,04164-3 also boasts user-friendly features, including a programmable timer and multiple fan speeds, allowing users to customize the airflow according to their preferences. Additionally, the quiet operation ensures that it does not disrupt daily activities or sleep, making it perfect for nighttime use.

In summary, the Guardian Technologies 02010-2,04164-3 air purifier combines advanced filtration technology, UVC light purification, and user-friendly features in a sleek design. It is an excellent choice for anyone looking to improve indoor air quality and create a healthier living environment.