5
2. If the supply cord is damaged, it must be replaced by the manufacturer or its service agent
or a similar qualified person.
3. If the fuse on PC board is broken please change it with the type of T 3.15A /250VAC.
4. The wiring method should be in line with the local wiring standard.
1. Applicable ambient temperature range:

The machine is adaptive in following situation

5. The power cable and connecting cable are self-provided.
For series 142, 182 the power cable should be H05RN-F 3G 2.5mm2.
For series 242 the power cable should be H05RN-F 3G 4.0mm2.
The connecting cable should be H05RN-F 4G 0.75mm2.
All the cables shall have got the European authentication certificate. During installation,
when the connecting cables break off, it must be assured that the grouding wire is the last
one to be broken off.
6. The breaker of the air conditioner should be all-pole switch; and the distance between its
two contacts should not be no less than 3mm. Such means for disconnection must be
incorporation in the fixed wiring.
7. The indoor unit installation height is at least 2.5m.
8. The distance between its two terminal blocks of indoor unit and outdoor unit should not
be over 5m. If exceeded, the diameter of the wire should be enlarged according to the local
wiring standard.
9. The waste battery shall be disposed properly.
Safety Precautions
Rated Maximum Minimum
27 32 18
19 23 14
35 43 10
24 26 6
20 27 15
14.5 -- --
7 24 -7
6 18 --
Cooling
Heating
Indoor
outdoor
DB C
WB C
DB C
WB C
Indoor
outdoor DB C
WB C
DB C
WB C
Cooling
Heating
Indoor
outdoor
Rated Maximum Minimum
27 32 18
19 23 14
35 43 -5
24 26 --
20 27 15
14.5 -- --
7 24 -7
6 18 --
DB C
WB C
DB C
WB C
Indoor
outdoor DB C
WB C
DB C
WB C
For *.EAA :
For *.ERA :