Haier ES35V-P2, ES25V-P2, ES15V-P2 user manual Technical data ∙ Packing list

Models: ES35V-P2 ES15V-P2 ES25V-P2

1 2
Download 2 pages 45.54 Kb
Page 2
Image 2
Technical data ∙ Packing list

Manual background Installation warning

During installation, adequate space must be reserved for future maintenance and repair (at least 300 mm). If the water heater is installed within decoration boards, the right board shall be removable to facilitate removing the plastic cover during maintenance.

Tap water inlet pressure shall be no less than 0.05MPa and the maximum pressure shall not exceed 0.75MPa.

Electric water heater shall be installed indoors with ambient temperature above 0°C. The pipes shall be collectively laid. Hot water outlet shall not be too far from use points. In case farer than 8 m, hot water pipe shall have a thermal insulation to minimize heat loss.

load bearing walls or air brick walls must have corresponding protective measures like additional support, wall-through screws or back boards.

tank or pipes leak, nearby or lower facilities shall not be damaged. The installation location shall avoid being above toilet bowl, bathtub, washbasin or doorframe, where will cause a suppressed or unsafe feeling to users.

Do not confuse inlet and outlet water pipes. Safety valve shall be installed at designated position with no

Use a test pencil to check whether the live line and null line are wrongly connected. Power may only be

connections. The power supply should also conform to the heater’s requirements.

To avoid danger caused by accidental reset of heating breaker, the power for the heater cannot be supplied by timer and other external switch devices or connected to circuit with frequent switching for facility use.

In order to avoid unforeseen accidents, only install components Haier-provided . Do not switch or exchange parts yourself. If components are damaged, you must contact the company’s repair center and use the parts supplied by Haier. If to the user fails to follow the requirement above, Haier will not be responsible for any direct or indirect damages caused hereof.

4Press SET key to calibrate the clock.

Press the SET+, to set the hour; Press the SET key again,

+, to set the minute; After setting, press SET

the value blinks for 6 seconds without any further operation, the system will automatically enter next

Under real-time heating mode, the heater will automatically heat the water or maintain the temperature near the set value. (If the set temperature is lower than 55°C, the heater will heat again once the temperature is lower than the set value by 5°C; If the set temperature is between 55°C and 75°C, the heater will heat again once the temperature is lower than the set value by 10°C.)

Manual background Preset Bath Mode

This product is equipped with preset bath function. Activate the preset bath function to set the preset bath time, power and temperature. If no operation is carried out for 2 minutes after that, the heater will enter into power saving mode (display on and current time only). It will also calculate the heating time, and heat the water to the preset temperature automatically before the preset time.

1Carry out Steps 1~4 of the real-time heating mode

2Press the TIMER key, the preset bath icon on displays.

3Press SET key to set the preset time

Press the SET+, to set the hour; Press the SET key again,

+, to set the minute; After setting, press SET

the value blinks for 6 seconds without any further operation, the system will automatically enter next

Note: If the actual temperature doesn't reach the set temperature at the preset time, the heater will extend the heating time by 30 minutes automatically. After 30 minutes the heater will stop heating no mater

Manual background Introduction of control panel

1

Actual temperature

8

HeatingTemp. icon Blinking,

2

Set temperature

 

indicates heating is in process;

3

Power

 

temperature is maintained at

 

set temperature once it stops

4

Current time

 

 

blinking.

5

Current time/

 

9

 

 

temperature increase

Preset stop-heating)

 

 

 

key

 

 

0

Preset bath, preset stop-heating

6

Power selection key

 

setting key

7

Time setting key

 

A

 

 

 

 

1

C urrent Temp.

 

2

H ea ting T emp.

 

 

Norma l F a s t T urbo

3

kW

4

O n

 

5

 

6

S P E E D T IM E R

7

S E T

8

9

0 A

the temperature reaches to the set temperature or not.

If by the preset time the actual temperature is that of the set temperature, but the actual temperature drops by 5°C by the preset time, the heater will re-heat the water. Once the preset time is reached, it will stop heating whether or not the water reaches the set temperature.

Manual background Preset Stop-heating Mode

This product is also equipped with preset stop-heating mode, i.e. the heater will automatically stop-heating at the appointed time.

1Carry out Steps 1~4 of the real-time heating mode

2Press the TIMER key repeatedly, the preset stop-heating icon Manual background displays

3Press the SET key to set the preset stop-heating time

Press the SET key, how-to is the same as mode 3 of preset bath

Manual background Real-time Heating Mode

is water leakage at the respective joints before connecting power. Once power is connected, the panel will show full display for 1 second, accompanied by a buzzer sound. The heater will then enter into shutdown state as before.

1Press Manual background key to switch on the heater

Press Manual background key for the heater to interchange between standby state (with clock display only) and working state.

2Press +, keys to set the temperature to (35~75°C)

The HeatingTemp. value icon on the control panel will blink and changes correspondingly. Once the desired value is reached press SET Manual background

3Press SPEED key repeatedly to select the heating power

This product provides three power settings for your selection. Low (1kW), Medium (2kW), High (3kW).

3

Preset bath and preset stop-heating can be set simultaneously. Once the settings are activated, water heater will automatically start heating the water to reach the preset temperature before the preset On time based on the current time and preset time. In the time between On and O￿, water heater is on real-time heating mode (once the water temperature drops 5 degree than the preset temperature, heating will be started again). The water heater will automatically stop heating when reaches the O￿ time.

Note: If the O￿ time is within the execution time of preset bath, then the Water heater will ￿rst stop heating for 1min, then continue the heating till ON time.

Manual background Installation of remote control unit holder

Use the correct screws in the accessories to secure the remote control unit holder onto a suitable position on the wall; and insert the remote control unit into the holder (see illustration below).

4

Manual background Remote control unit panel

Manual backgroundManual background Used to adjust the temperature value

Explanation:The use of the buttons on the remote control unit is the same as that for the

Item

Unit

ES15V-P2

ES25V-P2

ES35V-P2

 

 

 

 

 

Waterproof grade

/

IPX4

IPX4

IPX4

 

 

 

 

 

Mixing factor

%

13

5

4

buttons on the control panel.

Note: When using the remote control unit it is best to use it at close distance and at a perpendicular angle. When the battery in the remote control unit is completely exhausted, please remove the cover on its back using a coin to turn the knob in the direction as indicated, then remove the button battery inside and replace it with

prevent explosion. They should be disposed of in accordance with regulations.

Manual background Cleaning and maintenance

Warning

maintenance may cause severe injury or damage.

SPEED SET TIMER

Tap water pressure

MPa

No less than

No less than

No less than

0.05MPa

0.05MPa

0.05MPa

 

 

Average temperature of hot

oC

64

68

64

water outlet

 

 

 

 

Re-heating time

min

14

21

41

(a temperature rise of 50oC)

Diameter of power wire

mm2

3×1.5

3×1.5

3×1.5

Remarks: 1. The permitted error limit of net weight above is ±10%.

2.The values for mixing factor, average temperature of hot water outlet, re-heating time (a temperature rise of 50°C) are all measured under the maximum power condition.

Manual background Disconnect power supply before cleaning. Gently wipe with wet cloth dipped with a little of mild detergent. Do not use gasoline or other solvents. Finally dry with dry cloth. Keep water heater dry. Do not use cleansers containing grinding agent (e.g. toothpaste), acids, chemical

elements and tank liner of water heater shall be cleaned once in three years. Take care not to damage protection layer on heating elements and tank liner inner surface. According to

maintenance is needed, please contact local service station.

Friendly reminder:

1.In long-term out-of-use or maintenance of the heater, you can close the city water pipe valve and set the mixing valve to the highest water temperature rate after opening the safety valve handle. Move up the safety valve handle to drain the tank.

switching on the water heater, exhausting gas possibly retained in the pipeline. In this case, in good condition.

Technical data Packing list

Manual background Parameters

Item

Unit

ES15V-P2

ES25V-P2

ES35V-P2

 

 

 

 

 

Rated voltage

V

230

230

230

 

 

 

 

 

Rated frequency

Hz

50

50

50

 

 

 

 

 

Rated pressure

MPa

0.80

0.80

0.80

 

 

 

 

 

Power

W

1000/2000/3000

1000/2000/3000

1000/2000/3000

 

 

 

 

 

Net weight

kg

10

14

17

 

 

 

 

 

Rated temperature

oC

75

75

75

Volume

L

15

25

35

 

 

 

 

 

 

Dimensions

 

 

 

 

 

 

(Figure 4)

 

a

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Front

 

Side

 

 

Cutaway

d

Rear

 

 

 

 

 

 

 

 

C view

b

view

 

 

view

e

view

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Model

a

b

 

c

 

d

e

 

 

 

ES15V-P2

316mm

291mm

623mm

 

152mm

100mm

 

 

 

ES25V-P2

378mm

362mm

616mm

 

152mm

100mm

 

 

 

ES35V-P2

415mm

398mm

663mm

 

152mm

100mm

 

A Hot water outlet

B Cold water inlet

C Tank

D Heating element E Anode rod

F Thermometer tube G Wall-mounting bracket

Remarks: The permitted error limit of above parameters is ±10%.

Manual background Packing list

Name

Electric

Safety valve

Expansion

User's

Connecting

Remote control,

Accessories

Quantity

water

Drain hose

hook

manual

Remote control

Model

line (PCS)

pack (Unit)

heater (Set)

(Unit)

(PCS)

(Copy)

 

unit holder (Set)

 

ES15V-P2

1

1

2

1

1

1

1

 

 

 

 

 

 

 

 

ES25V-P2

1

1

2

1

1

1

1

 

 

 

 

 

 

 

 

ES35V-P2

1

1

2

1

1

1

1

 

 

 

 

 

 

 

 

5

6

Page 2
Image 2
Haier ES35V-P2, ES25V-P2, ES15V-P2 user manual Technical data ∙ Packing list