6767

Troubleshooting

Symptom

 

Things to Check

Solutions

 

1 Whether the water supply has

 

 

 

stopped or whether the water

Check

No water

 

pressure is too low

 

2

Whether the water-usage

 

 

 

 

 

point is blocked or whether

Check and clean

 

 

the hot water valve is opened

 

 

1 Whether hot water outlet is

Check and open

 

 

not opened

 

 

 

 

 

 

Increase the temperature to the

 

 

 

required value. Once the water is

 

2 Whether the water tempera-

heated to the pre-set temperature,

Only cold water but

 

ture is adjusted

control flow volume of cold and

 

 

hot water using the moderating

the heating indica-

 

 

 

 

mixing valve.

tor lamp is lit

 

 

3

Heating time is too short

 

 

 

 

 

and set temperature is not

Continue heating

 

 

achieved

 

 

4 Whetehr heating pipe is

Confirm this is not due to the rea-

 

sons ①②③, then contact Mainte-

 

 

damaged

 

 

nance Department

 

 

 

 

1 Whether power is properly

Check power socket

Only cold water and

 

connected

 

 

the heating indica-

2

Whether thermostat is out of

Confirm that this is not due to rea-

tor lamp is not lit

son , then contact Maintenance

 

control

 

 

Department

 

 

 

Heating indicator

1 Water has not reached the set

Continue heating

 

temperature

 

light is on all the

2

Whether thermostat is out of

Confirm it is not due to reason ,

time

then contact Maintenance Depart-

 

control

 

 

ment

 

 

 

Water volume is

 

 

 

sometimes large or

Whether water pressure

Set lower mixing valve or ensure

small, or water is

is stable

water pressure is stable before

sometimes hot or

use

 

 

cold

 

 

 

 

1 Whether the present tempera-

Calibrate using the method stipu-

Small hot water

 

ture setting is too low

lated in the Instruction Manual

outflow volume

2 Whether water pressure is too

Set lower mixing valve

 

 

much

 

Proprietary No.**********0040503115

V V

 

Safety Notices (Please read before use)

 

 

 

 

 

 

 

 

 

Meanings of Icons

 

Compulsory

 

Essential

 

 

 

 

Prohibited

 

 

 

 

Matters

 

Matters

 

 

 

 

 

Forbidden

 

Warning

 

Caution

 

 

 

 

 

 

Haier Home Water Heater

Instruction manual

ES50V-G1(H)

ES70V-G1(H)

ES100V-G1(H)

ES100V-R1(H)

Please read this Instruction Manual carefully before use.

Please retain this manual for future reference.

Electrical Diagram·Exterior and accessories·Technical parameters

Electrical Diagram

L : Live wire (brown)

MT

BT

N : Zero line (blue)

 

 

MT : Manual-reset thermostat

 

EH

BT : Adjustable thermostat

L

 

HL : Heating indicator light

HL

 

Immediately cut off power supply and contact our Service Center once the water heater does not work properly or emits burnt smell.

 

 

 

 

 

This icon is used by Haier

 

 

 

 

 

 

Water Heaters to indicate

Forbidden

 

 

 

 

 

 

 

 

 

 

"safety warning experts". It

 

 

 

 

 

indicates that the product

 

 

 

 

 

 

is equipped with special

 

 

 

 

 

 

technology that constantly

 

 

monitors the status of your earth line,

Forbidden

 

to ensure safety during showering.If

 

 

the icon is lit, it means that there is

 

 

electricity in the earth line. You should

 

 

immediately stop using the water

Forbidden

 

heater and disconnect the power plug.

 

Do not touch the outer casing of any

 

 

electrical appliances in your home.

 

 

Remember to also contact the local

Forbidden

 

After-sales department or property

 

management company in order for

 

 

them to engage qualified electricians

 

 

to carry out a system check until the

 

 

icon is no longer lit.

Forbidden

 

The product is only available for

 

 

alternating current.

 

Warning

To ensure safety, the water heater

Warning

 

should be connected to independent

 

 

sockets (do not use adapters), with re-

 

 

liable earthing. In addition, the power

 

Earthing socket must conform to national stan-

 

 

dards. Use of water heater without

Warning

 

reliable earthing is strictly prohibited.

 

 

Use pen multimeter to check whether

 

 

the live line and zero line are reverse.

 

 

Do not use damaged wire and power

Caution

 

socket. Promptly clean the dust on the

 

Warning

power plug and socket.

 

Check the power meter and the elec-

 

 

 

 

tric wire's diameter to ensure that they

 

 

comply with the rated current for the

 

Warning

water heater. Where necessary en-

 

gage qualified electrician to check the

 

 

electric circuit.

Forbidden

Do not touch the plug with wet hands, and make sure that the water heater,

plug socket do not come into contact Caution Forbidden with water. If they are accidentally wet,

they must be checked by professions appointed by our company before us- ing, in order to prevent electrocution.

Storing of inflammable and explosive items near the water heater is strictly prohibited.

Do not connect to power when install- ing or repairing the water heater.

Non-professionals are strictly prohib- ited from carrying out repairs, m a i n - tenance, dismantling or revamping of the water heater.

Installation of water heater outdoors is strictly prohibited.

Do not install the water heater in an environment which is susceptible to ice-formation. Ice will cause the con- tainer and water pipe to break, lead- ing to scalding and water leakage.

Please take precautionary measures during cold weather, in order to pre- vent damage to water heater from freezing.

If the soft power cable is damaged, it must be replaced by professional staff from the manufacturers or Main- tenance Department in order to avoid danger.

Take care not to be scalded by heated water.

·Touching of hot water valve and pipes is strictly prohibited.

·Make sure to check the water tem- perature before use; use only when it feels suitable.

Do not use water from the water heat- er for drinking or similar purposes.

Please cut off the power supply if the water heater was not used for an ex- tended period of time. Drain the water heater of all water according to the in- structions in the chapter on Cleaning and Maintenance.

EH : Heating pipe

N

E

E

E: Earth line (yellow-green; dual color)

Exterior and accessories

Front view

Rear view

Side view

Cross-section view

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A : Hot water outlet

B : Cold water inlet

C : Inner chamber

 

 

 

D : Temperature measurement pipe

 

E : Heating pipe

 

 

 

F : Magnesium rod

G : Wall hook

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Model No.

Capacity

Net

a1

b1

c1

d1

e1

f1

(L)

weight(kg)

(mm)

(mm)

(mm)

(mm)

(mm)

(mm)

 

ES50V-G1(H)

50

21

410

420

775

100

200

220

ES70V-G1(H)

70

26

410

420

980

100

200

480

ES100V-G1(H)

100

33

410

420

1300

100

200

730

ES100V-R1(H)

100

33

410

420

1300

100

200

730

Note:1. The margin of error for the above parameters (measurements, weight) is ±10%.

2.The thermometer is not a precision instrument. It consists of three areas denoted by blue; orange and red, which indicate the temperature of water in the inner chamber from low to high respectively.

Technical parameters

Ltem

Unit ES50V-G1(H)

ES70V-G1(H)

ES100V-G1(H) ES100V-R1(H)

 

 

0.80

0.80

0.80

0.80

 

 

 

 

2150

2150

2150

2000

Water pressure

MPa

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

CSH10D0037_en.indd 1

2

Page 1
Image 1
Haier ES50V-G1(H) instruction manual Troubleshooting, Electrical Diagram, Exterior and accessories, Technical parameters

ES70V-G1(H), ES100V-G1(H), ES50V-G1(H), ES100V-R1(H) specifications

Haier has long been a leader in consumer electronics, and its range of air conditioners has made significant strides in performance, energy efficiency, and advanced technology. Among these products are the Haier ES100V-R1(H), ES50V-G1(H), ES100V-G1(H), and ES70V-G1(H) models, each tailored to meet diverse cooling and heating needs, while ensuring comfort and convenience across various living spaces.

The Haier ES100V-R1(H) is a powerful model designed for larger areas. It features a robust cooling capacity, allowing it to swiftly lower temperatures even in sweltering conditions. The unit is equipped with a state-of-the-art inverter technology that not only enhances cooling efficiency but also significantly reduces energy consumption, helping users save on electricity bills. Additionally, its environment-friendly refrigerant contributes to reducing the overall carbon footprint, aligning with global sustainability goals.

In contrast, the Haier ES50V-G1(H) caters to smaller rooms or individual spaces. This model combines compact design with high performance, offering energy-efficient cooling without taking up too much space. It utilizes advanced filtration technology, ensuring that the air circulated is clean and free from allergens, which is particularly advantageous for those with respiratory issues.

The ES100V-G1(H) aligns closely with the ES100V-R1(H) in terms of capacity and features but includes added smart technology capabilities. Users can control this unit via a mobile app, allowing for remote operation, scheduling, and monitoring energy consumption. This smart connectivity provides users with unparalleled convenience and enhances the overall user experience.

Lastly, the Haier ES70V-G1(H) is ideal for mid-sized rooms, balancing powerful performance with energy efficiency. It also embraces advanced inverter technology, ensuring a whisper-quiet operation that is especially appreciated in bedrooms or study areas. The unit incorporates an intelligent defrosting mechanism, which optimizes performance during colder months, maintaining a comfortable environment regardless of the external temperature.

Featuring sleek designs and user-friendly interfaces, these Haier models not only promise efficient cooling and heating but also blend seamlessly into modern home aesthetics. With their commitment to innovation, energy efficiency, and user comfort, Haier's ES series air conditioners remain a preferred choice for consumers looking to enhance their indoor living experience.