Pressure-relief hole (connected to water drainage pipe)

Installation instruction

 

Hot water

 

 

 

Cold water

 

outlet

 

 

 

pipe

 

 

 

 

 

 

 

Direction of cold water

 

 

 

 

 

 

 

 

 

Nozzle

Hot water

 

 

 

 

 

Direction of hot water

 

 

 

 

 

pipe

 

 

 

 

 

 

 

 

 

 

 

Cold water inlet

 

 

 

 

 

 

 

 

Safety valve

Installing safety valve

Install the safety valve which has a rated pressure of 0.80MPa (its

 

connection is G1/2) into the water intake pipe with the arrow on the

Safety valve

safety valve pointing at the water heater. When the water heater is

Mini handle

heated by electricity, a small amount of water will flow from the safety

 

valve's pressure relief hole due to the expansion of water in the heat-

 

er. This is normal. The pressure-relief hole should be connected to the

 

atmosphere and free from blockage at all times.

 

Installation method for safety valve's drainage pipe: Attach an end of the water drainage pipe onto the pressure relief hole on the safety valve. You may cut the water drainage pipe to make it shorter, or ex- tend it depending on the situation. Connect to the other end of the water drainage pipe to the lower water outlet. This will prevent the water from the pressure relief hole from splashing. The water drainage

pipe connected to the safety valve should be installed in a slanted manner and in an environment which is not prone to frost.

Installation Precautions

When installing the water heater, certain space should be reserved (not less than 250mm from the top and bottom, and not less than 700mm from the front and the sides) for ease of subsequent maintenance and repair. If the water heater was to be built into clip boards, the bottom section of the clip board should be movable for ease of removal of plastic cover during maintenance.

Make sure the pressure on the water intake is not less than 0.05MPa, and not more than 0.75MPa.

3

Installation Precautions

The water heater should be installed indoors in a place where the ambient temperature is above 0ºC. The pipes should be closely laid out. The hot water outlet should be too far away from the point of usage. If the distance exceeds 8 meters, the hot water pipe should have in- sulation protection, in order to prevent heat loss.

The wall on which the water heater should be strong such as it is able to withstand four times the weight of the water heater when filled with water. If the wall was not weight-bearing wall or made of hollow bricks, adequate protective measures such as addition of support and high-strength wall screw with back panel should be adopted.

The water heater should be installed in places such as it is easy to use and maintain and with floor drain. In order that it will not cause damage to nearby facilities or those in the lower levels during a leakage of the water tank or water pipe. It should not be installed over toilet bowls, bathtub, wash basin or door frame in order that users do not feel oppressed or insecure.

Power socket for the water heater should be installed in dry places which do not easily come into contact with water, in order not to affect the heater’s normal operation (it would be best equipped with protective cover).

Do not reverse the installation for the water intake and outlet. The safety valve should be in- stalled in the designated position and not moved without permission. The safety valve's pres- sure-relief hole should be connected to the atmosphere and free from blockage at all times.

Use pen multimeter to check whether the live line and zero line are reverse. Turn on power supply only when you have ensured that the heater is filled with water and that there is no wa- ter leakage. The power supply should also conform with requirements.

Safety reminder: In order to prevent accidents, please use our company's accessories during installation. Do not replace them on your own or use substitutes. Please make sure to contact our Maintenance Department if the accessories are damaged and replace them with the accessories supplied by our company. Our company shall not be liable for any direct or indirect losses caused as a result of accidents for failure to comply with the aforesaid.

All water pipes should be installed by qualified water pipe installation workers. The pipelines should comply with the national standards and regulations on the prohibition of prevention tools to draw water to water source pipelines by way of inverse siphon, as well as local building codes.

Installation method

Must be installed by personnel in our company's After-sales Department or designated installation personnel.

The water heater is wall-mounted type.

Determine the installation location of the water heater and drill 4 holes of ￿12mm and 65mm deep in the wall with a churn drill. Insert the expansion hooks and expansion bolts into corresponding holes and fasten them. Then, lift the water heater to put the hangers on the hooks and bolts. Mount the flat shims, connecting wires on the back of the water heater and nuts on the bolts in turn (as shown in Fig. 1) and fasten the nut. Then, check if they are firm. Refer to “Install relief valve" to install the relief valve and other accessories (only for installation reference). Remember to use Teflon tape to avoid leakage.

Expandable hook

Wall hook

Fig.1

For ease of installation and removal of water heater, we would recommend that G1/2 loose joints be installed at appropriate locations on the water inlet and outlet pipes of the water heater. Determine the position of the hot water supply. Connect the water intake and outlet pipe together with the water pipe to the positions reserved for use of hot water. Hot water pipe should preferably not be too long in order to prevent heat loss.

Note: Make sure that the water heater is securely attached to the hook before letting it go; otherwise it may drop and cause injury or property damage.

4

Instruction manual

Operation

After completion of installation, make sure to turn on the water intake valve and mix- ing valve since there is no water in the inner chamber. Turn the mixing valve to the maximum for hot water outlet. Turn off the out-flow valve when water flows out from the sprinkler or the water outlet (indicating that the container is filled with water). Turn off the water outlet valve. Inspect all connections to ensure that there is not water leakage be- fore connecting to power.

1Adjust the water temperature knob at the bottom of the water

heater to set the temperature.

The maximum temperature setting is 75ºC

 

 

Temperature adjustment knob: Turn the

 

 

knob gradually clockwise to raise the

 

 

temeprature setting. The knob will not

 

 

continue to turn once it reaches maximum

 

 

temperature setting. Turn it anti-clockwise

 

 

graudally to reduce the temperature set-

OFF

MAX

ting.

If the heating indicator light is lit, it means that the water heater is heating

If the heating indicator is power off, it means that heating is finished and it. will enter heating insulation state or. get closed totally.

2

Observe thermometer the current

 

 

 

water temperature.

Thermometer

Heating indicator light

Power will be automatically cut off when the water temperature reaches the set tem- perature. Once it lowers to certain temperature power will be automatically connected.

When the water pressure is 0.80MPa and the pressure-relief hole on the safety valve emits large volume of water, it means that the water pressure is excessive.

In such case, please notify the After-sales Department.

Things to note during use

1Do not connect the power before filling the inner chamber with water in order to prevent damage to the water heater.

2Adjust the water temperature to the suitable level before use in order to prevent scalding.

3As long as the hot water is adequate, set a lower temperature to reduce heat loss, high temperature corrosion and scaling, thus extending the water heater’s lifespan.

4Do not place inflammable substances such as petrol near the water heater; otherwise it may cause fire.

5To avoid danger caused by accidental resetting of the heating breaker, the power for the heat cannot be supplied by timer and other external switch devices or connected to circuit with frequent switching for facility use.

5

CSH10D0037_en.indd 2

Cleaning and Maintenance·Packing List

Cleaning and Maintenance

Warning!

The water heater must be repaired or maintained by qualified professionals. Improper methods may cause serious injury or damage to property.

Cleaning

￿External cleaning

Power must be switched off before cleaning the water heater.

Take a wet cloth and dab it with small quantity of neutral detergent. Lightly wipe the water heat- er. Do not use petrol or other solvents. Finally use a dry cloth to wipe; make use to dry the water heater thoroughly. Make sure not to use detergents containing abrasive agents (e.g. toothpaste); acidic substances; chemical solvents (e.g. alcohol) or polish to clean the water heater.

￿Internal cleaning

In order to ensure that the water heater will work with high efficiency, clean the heating tube and inner chamber once every three years. Take care not to damage the exterior of the heat- ing pipe and the protective layer on the surface of the inner chamber. Depending on the local water quality and usage habit, the magnesium rod should be regularly replaced. If mainte- nance is required, please contact the local Maintenance Department.

Check

When the water heater is in use, the safety valve should be checked once every month. To check it, turn the safety valve's small handle on the side of the water intake (take care not to hurt your hand). If there is water flowing out, the safety valve is working normally. Please contact the local After-sales Department if no water flows out. In the event of damage to the safety valve, please replace it with a safety valve of similar specifications.

Regularly engage service personnel to carry out safety inspection and promptly clear the wa- ter heating pipes of the scale. Check also the consumption of the magnesium rod; change it if consumption becomes excessive.

Not in use for an extended period of time

If the water heater is not used for an extended period of time, please carry out the following steps:

1Turn off the water pipe valve.

2Screw the water drainage pipe to the safety valve's pressure-relief hole; turn on the safety valve handle.

3Turn the hot water valve to the maximum (at the same time unscrew the soft sprinkler pipe from the water outlet valve; take care not be scalded by hot water), drain the inner chamber of water.

When the water heater needs to be used again, our recommendation is to open hot water valve before switching on the power in order to prevent accidents. Allow any gas that may be trapped in the pipe to be discharged. Do not smoke or allow other exposed fire to be near the opened valve. At the same time, make sure to carefully examine all the parts of the water heater and ensure that they are in a perfect condition. Make sure to fill the inner chamber with water before use.

Packing list

Quantity Name of parts

Electric

Safety valve

Expand-

Expand-

Instruction

 

water heater

drainage pipe

able screw

able Hook

Manual

Product Model No.

(unit)

(set)

(pcs)

(pcs)

(copy)

ES50V-G1(H)

 

 

 

 

 

ES70V-G1(H)

1

1

2

2

1

ES100V-G1(H)

 

 

 

 

 

ES100V-R1(H)

 

 

 

 

 

6

2010-4-28 9:18:40

Page 2
Image 2
Haier ES100V-R1(H), ES70V-G1(H), ES50V-G1(H), ES100V-G1(H) Installation instruction, Cleaning and Maintenance·Packing List

ES70V-G1(H), ES100V-G1(H), ES50V-G1(H), ES100V-R1(H) specifications

Haier has long been a leader in consumer electronics, and its range of air conditioners has made significant strides in performance, energy efficiency, and advanced technology. Among these products are the Haier ES100V-R1(H), ES50V-G1(H), ES100V-G1(H), and ES70V-G1(H) models, each tailored to meet diverse cooling and heating needs, while ensuring comfort and convenience across various living spaces.

The Haier ES100V-R1(H) is a powerful model designed for larger areas. It features a robust cooling capacity, allowing it to swiftly lower temperatures even in sweltering conditions. The unit is equipped with a state-of-the-art inverter technology that not only enhances cooling efficiency but also significantly reduces energy consumption, helping users save on electricity bills. Additionally, its environment-friendly refrigerant contributes to reducing the overall carbon footprint, aligning with global sustainability goals.

In contrast, the Haier ES50V-G1(H) caters to smaller rooms or individual spaces. This model combines compact design with high performance, offering energy-efficient cooling without taking up too much space. It utilizes advanced filtration technology, ensuring that the air circulated is clean and free from allergens, which is particularly advantageous for those with respiratory issues.

The ES100V-G1(H) aligns closely with the ES100V-R1(H) in terms of capacity and features but includes added smart technology capabilities. Users can control this unit via a mobile app, allowing for remote operation, scheduling, and monitoring energy consumption. This smart connectivity provides users with unparalleled convenience and enhances the overall user experience.

Lastly, the Haier ES70V-G1(H) is ideal for mid-sized rooms, balancing powerful performance with energy efficiency. It also embraces advanced inverter technology, ensuring a whisper-quiet operation that is especially appreciated in bedrooms or study areas. The unit incorporates an intelligent defrosting mechanism, which optimizes performance during colder months, maintaining a comfortable environment regardless of the external temperature.

Featuring sleek designs and user-friendly interfaces, these Haier models not only promise efficient cooling and heating but also blend seamlessly into modern home aesthetics. With their commitment to innovation, energy efficiency, and user comfort, Haier's ES series air conditioners remain a preferred choice for consumers looking to enhance their indoor living experience.