Installation instruction
| Hot water | | | | Cold water |
| outlet | | | | pipe |
| | | | | | | Direction of cold water |
| | | | | | |
| |
Nozzle | Hot water | | | | | | Direction of hot water |
| | | | |
pipe | | | | | | |
| | | | | Cold water inlet |
| | | | |
| | | Safety valve |
Installing safety valve
Install the safety valve which has a rated pressure of 0.80MPa (its | |
connection is G1/2) into the water intake pipe with the arrow on the | Safety valve |
safety valve pointing at the water heater. When the water heater is | Mini handle |
heated by electricity, a small amount of water will flow from the safety | |
valve's pressure relief hole due to the expansion of water in the heat- | |
er. This is normal. The pressure-relief hole should be connected to the | |
atmosphere and free from blockage at all times. | |
Installation method for safety valve's drainage pipe: Attach an end of the water drainage pipe onto the pressure relief hole on the safety valve. You may cut the water drainage pipe to make it shorter, or ex- tend it depending on the situation. Connect to the other end of the water drainage pipe to the lower water outlet. This will prevent the water from the pressure relief hole from splashing. The water drainage
pipe connected to the safety valve should be installed in a slanted manner and in an environment which is not prone to frost.
Installation Precautions
When installing the water heater, certain space should be reserved (not less than 250mm from the top and bottom, and not less than 700mm from the front and the sides) for ease of subsequent maintenance and repair. If the water heater was to be built into clip boards, the bottom section of the clip board should be movable for ease of removal of plastic cover during maintenance.
Make sure the pressure on the water intake is not less than 0.05MPa, and not more than 0.75MPa.
3
Installation Precautions
The water heater should be installed indoors in a place where the ambient temperature is above 0ºC. The pipes should be closely laid out. The hot water outlet should be too far away from the point of usage. If the distance exceeds 8 meters, the hot water pipe should have in- sulation protection, in order to prevent heat loss.
The wall on which the water heater should be strong such as it is able to withstand four times the weight of the water heater when filled with water. If the wall was not weight-bearing wall or made of hollow bricks, adequate protective measures such as addition of support and high-strength wall screw with back panel should be adopted.
The water heater should be installed in places such as it is easy to use and maintain and with floor drain. In order that it will not cause damage to nearby facilities or those in the lower levels during a leakage of the water tank or water pipe. It should not be installed over toilet bowls, bathtub, wash basin or door frame in order that users do not feel oppressed or insecure.
Power socket for the water heater should be installed in dry places which do not easily come into contact with water, in order not to affect the heater’s normal operation (it would be best equipped with protective cover).
Do not reverse the installation for the water intake and outlet. The safety valve should be in- stalled in the designated position and not moved without permission. The safety valve's pres- sure-relief hole should be connected to the atmosphere and free from blockage at all times.
Use pen multimeter to check whether the live line and zero line are reverse. Turn on power supply only when you have ensured that the heater is filled with water and that there is no wa- ter leakage. The power supply should also conform with requirements.
Safety reminder: In order to prevent accidents, please use our company's accessories during installation. Do not replace them on your own or use substitutes. Please make sure to contact our Maintenance Department if the accessories are damaged and replace them with the accessories supplied by our company. Our company shall not be liable for any direct or indirect losses caused as a result of accidents for failure to comply with the aforesaid.
All water pipes should be installed by qualified water pipe installation workers. The pipelines should comply with the national standards and regulations on the prohibition of prevention tools to draw water to water source pipelines by way of inverse siphon, as well as local building codes.
Installation method
Must be installed by personnel in our company's After-sales Department or designated installation personnel.
The water heater is wall-mounted type.
Determine the installation location of the water heater and drill 4 holes of 12mm and 65mm deep in the wall with a churn drill. Insert the expansion hooks and expansion bolts into corresponding holes and fasten them. Then, lift the water heater to put the hangers on the hooks and bolts. Mount the flat shims, connecting wires on the back of the water heater and nuts on the bolts in turn (as shown in Fig. 1) and fasten the nut. Then, check if they are firm. Refer to “Install relief valve" to install the relief valve and other accessories (only for installation reference). Remember to use Teflon tape to avoid leakage.
Fig.1
For ease of installation and removal of water heater, we would recommend that G1/2 loose joints be installed at appropriate locations on the water inlet and outlet pipes of the water heater. Determine the position of the hot water supply. Connect the water intake and outlet pipe together with the water pipe to the positions reserved for use of hot water. Hot water pipe should preferably not be too long in order to prevent heat loss.
Note: Make sure that the water heater is securely attached to the hook before letting it go; otherwise it may drop and cause injury or property damage.
4