Figure 1

3

DW

H

cooling
Capacity SEER CFM 80 85 90 95 100 105 110 115
HR18D2VAR HB2400VD1M20 M 17000 13 670 19210 19197 18020 17000 17237 16490 16712 15980
HR24D2VAR HB2400VD1M20 H 22500 13 900 25425 24683 23850 22500 22162.5 21825 21488 21150
HR30D2VAR HB3600VD1M22 L 28000 13 1125 31640 30716 29680 28000 27580 27160 26740 26320
HR36D2VAR HB3600VD1M22 H 35000 13 1240 39550 38395 37100 35000 34475 33950 33425 32900
heating
Capacity HSPF CFM -100 1020 30 40 5060
HR18D2VAR HB2400VD1M20 M 15000 7.8 670 4773 6418 8036 9682 11272.73 13264 15627 18000
HR24D2VAR HB2400VD1M20 H 20000 7.8 900 6364 8558 10715 12909 15030 17685 20836 24000
HR30D2VAR HB3600VD1M22 L 26000 7.8 1125 8273 11125 13930 16782 19539 22990 27087 31200
HR36D2VAR HB3600VD1M22 H 32500 7.8 1240 10341 13906 17412 20977 24424 28738 33859 39000

Table 2: System Capacity

Cooling Capacity with different outdoor temperature
Heating Capacity with different outdoor temperature
Outdoor
Indoor
ARI data of indoor
Outdoor
Indoor
ARI data of indoor
Indoor fan
speed
Indoor fan
speed