Haier HSU-12CG13, HSU-09CG13, HSU-14CG13 Cautions, The machine is adaptive in following situation

Models: HSU-14CG13 HSU-12CG13 HSU-09CG13

1 17
Download 17 pages 31.16 Kb
Page 4
Image 4
The machine is adaptive in following situation

Cautions

The machine is adaptive in following situation

1.Applicable ambient temperature range:

 

Indoor

Maximum: D.B / W.B

32oC/23oC

 

Minimum: D.B / W.B

18oC/14oC

Cooling

 

Outdoor

Maximum: D.B

43oC/26oC

 

 

Minimum: D.B

18oC

 

 

 

Indoor

Maximum: D.B

27oC

Heating

Minimum: D.B

15oC

Outdoor

Maximum: D.B / W.B

24oC/18oC

 

Minimum: D.B / W.B

-7oC/-8oC

2.If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar qualified person. The type of connecting wire is H05RN-F or H07RN-F

3.If the fuse on PC board is broken please change it with the type of T. 3.15A/250V.

4.The distance between the indoor unit and the floor should be more than 2m.

5.The wiring method should be in line with the local wiring standard.

6.After installation, the power plug should be easily reached.

7.The waste battery should be disposed properly.

8.The appliance is not intended to use by young children or infirm persons without supervision. 9.Young children should be supervised ensure that they do not play with the appliance.

10.The appliance must be installed on strong enough supporter.

11.The wiring diagram is attached inside the machine.